User guide

Initial System Administration
3-12 Issue 1 September 1995
i. Assign the time zone
j. Reboot the system
k. Run the switch-names audit (only applies to DS-integrated systems)
l. Check alarm status
m. Check hardware status
Task 14A: Set the DEFINITY AUDIX Clock
1. At the login prompt, enter craft.
The system displays the Password prompt.
2. Enter crftpw.
The system displays the Enter terminal type prompt.
3. Enter one of the following:
513 for a 513 BCT or 715 BCT; enter 513 also for a 610/615 BCT or
a PC with a 513 emulation package. (Since 513 is the default, you
can just press to select it).
4410 for a 4410 or 5410 terminal; enter 4410 also for a 610/615 BCT
or a PC with a 4410 emulation package.
4425 for a 4425 or 5425 terminal
5420 for a 5420 or 4415 terminal
g3-ma for a G3-MA
The system displays the DEFINITY AUDIX command line.
4. Type set time and press .
RETURN
RETURN