User guide
Task 13: Activate DEFINITY AUDIX Server Hardware
Options
Issue 1 September 1995
3-7
10. Move the cursor to the Multilingual? field. This indicates whether or not
multilingual announcement sets can be administered on a per subscriber
or class-of-service basis. The default value is n. Type y to enable the
Multilingual feature.
11. Move the cursor to the Maximum Number of IMAPI Sessions: field and,
using the information on the customer’s order, type 32, the allowable
number of sessions.
12. Move the cursor to the Hours of Voice Storage Purchaced field and enter
the hours of voice storage this customer has purchaced.
13. Move the cursor to the Total Hours on Disk field and enter the total hours
available on the disk supplied with the hardware.
14. Press the (F3) function key to save your changes or press
(F1) to cancel. Press (F3) again to confirm.
The system automatically logs off. If the Port Emulation Type was
changed, a system restart is automatically initiated. Wait for
OLDTRACELOG=/var/spool/audix/oldtrace to display on the
screen, then press to clear the screen and display the login
prompt.
15. Proceed to Task 13: Activate DEFINITY AUDIX Server Hardware Options.
Task 13: Activate DEFINITY AUDIX
Server Hardware Options
This task is required only if a TN2170 was installed and Intuity Message Manager
was purchased. Otherwise, proceed to Task 14: Perform Initial DEFINITY AUDIX
Administration. The System Parameters Imapi-Options screen cannot be
accessed if Intuity Message Manager was not purchased.
Check that the settings on the System Parameters Imapi-Options screen are as
specified on Worksheet C-2. Also check that the IMAPI Access and IMAPI
Voice File on the Subscriber and COS (class of service) screens are
activated. Refer to Worksheet C-8:
Add Subscribers
.
NOTE:
Prior to activating and installing the LAN options that will allow Intuity
Message Manager to work, inform the LAN system administrator to add the
AUDIX host name to the network domain name server. This will allow name
addressing to the AUDIX system. Also, a 104A Connecting Block must be
connected to the LAN prior to setting up this feature (see Task 5: Install the
DEFINITY AUDIX System Assembly).
ENTER CANCEL
ENTER
RETURN