User guide
Task 10: Finalize and Test the Hardware
Issue 1 September 1995
2-33
4. Check the alarm status.
a. With the cursor on the DEFINITY AUDIX system command line,
enter display alarms.
The system displays the Display Alarms
screen.
b. Check the ALARM TYPES fields for any active alarms (indicated by
a “y” next to the alarm type). Press (F3) to display the
alarms.
You should see a voice ports major alarm and possibly port
warnings because the ports are not administered yet. These are the
only alarms that you should expect.
c. Ignore the voice port alarms; however, resolve all other active
alarms. See
DEFINITY AUDIX System — Maintenance
,
585-300-110, for the procedures for identifying and resolving the
alarms.
5. Place the labels supplied with the DEFINITY AUDIX system hardware as
follows:
a. Place the label containing the DEFINITY AUDIX system shutdown
warning next to the cabinet Power switch.
b. Place the label with fan/filter cleaning information on the inside of
the switch cabinet door.
ENTER