User guide
Hardware Installation
2-20 Issue 1 September 1995
If the terminal does not display the login prompt when the DEFINITY
AUDIX system is in one of the above states, try pressing the
key a few times. If the login prompt still does not appear,
write down the state displayed on the LCD then see the
troubleshooting procedures for terminal connections in
DEFINITY
AUDIX System — Maintenance
, 585-300-110.
3. For CL integration, proceed to Task 8: Install the Control-Link Cable. For
DS integration, proceed to Task 9: Install the Printer (Optional).
Task 7D: Install a Terminal via 7400A Data Sets
This task describes how to connect a terminal via 7400A Data Sets to Port B (DS
integration only) of the MFB. (This task can also be used for remote connection to
DS or CL integration.)
Refer to Figure 2-10, Connecting a Terminal to the MFB via 7400 Data Sets, when
performing this task.
Figure 2-10. Connecting a Terminal to the MFB via 7400 Data Sets
NOTE:
You may use two 7400A data sets in this configuration. However, because
the 7400B data set is easier to set up and use, it is the one described in this
procedure on the terminal side. (The DEFINITY AUDIX system side of the
configuration requires the 7400A.) If you are using two 7400A data sets,
connect the second 7400A the same as the 7400B, but set the options as
described under
Using the Front Panel
in
7400A Data Module User’s
Manual
, 555-020-706.
RETURN
*NULL MODEM IS REQUIRED WHEN CONNECTING TO 715 BCT DCE PORT.
PORT B
ALB
CABLE
GROUP 311 CABLE
POWER
SUPPLY
*SEE
NOTE
POWER
SUPPLY
7400B
SITE-SPECIFIC
NETWORK
CONNECTIONS
7400A
PORT A
MFB
Y
CABLE
ALARM
BOARD
SWITCH
MULTI-
FUNCTION
BOARD