User guide
Hardware Installation
2-18 Issue 1 September 1995
If the terminal does not display the login prompt when the DEFINITY
AUDIX system is in one of the above states, try pressing the
key a few times. If the login prompt still does not appear,
write down the state displayed on the LCD then see the
troubleshooting procedures for terminal connections in
DEFINITY
AUDIX System — Maintenance
, 585-300-110.
k. Log in to the DEFINITY AUDIX system (see Task 9 for login details).
If you can log in successfully, the modem and terminal options are
set correctly.
4. For CL integration, proceed to Task 8: Install the Control-Link Cable. For
DS integration, proceed to Task 9: Install the Printer (Optional).
Task 7C: Install a Terminal via ADUs
This task describes how to connect a terminal via ADUs to Port B (DS integration
only) of the MFB. (This task can also be used for remote connection to Port A,
whether DS or CL integration.)
Refer to Figure 2-9, Connecting a Terminal to the MFB via ADUs, when
performing this task.
Figure 2-9. Connecting a Terminal to the MFB via ADUs
RETURN
POWER
SUPPLY
Z3A1
GROUP 311 CABLE D8AM
CABLE
ALB
PORT B
*NULL MODEM IS REQUIRED WHEN CONNECTING TO 715 BCT DCE PORT.
MULTI-
FUNCTION
BOARD
SWITCH
ALARM
BOARD
Y
CABLE
MFB
PORT A
Z3A4
HOUSE
WIRING
*SEE
NOTE
ADAPTER