20. Log in to the DEFINITY AUDIX system as craft. Wait for Active to appear
on the status line before continuing.
21. [less than 1 min]
Run
TEST TAPE CLEAN to reset the tape cleaning interval counter.
22. [1 min]
Check the Alarm Status at the top of the screen. If there are alarms, enter
DISPLAY ALARMS at the command line and take the appropriate
action to remove the alarms. Consult
DEFINITY AUDIX System —
Maintenance,
585-300-110 for information on removing alarms.
23. [10 min]
Call the DEFINITY AUDIX system and log in as a subscriber. Verify that the
DEFINITY AUDIX system is in service and working properly; create, send,
and retrieve a message.
24. [1 min]
Remove the language set tape. Insert a customer backup tape to be used
for the automated saves.
25. [10 min]
Run
ADD TAPE to equip the tape. Enter a new volume name in the Volume
Name field. (The new volume name must be different from the name
already in this field, if any.)
26. Press to invoke the add-tape operation. Ignore any warnings
about releases not matching. Check the status of the
ADD TAPE operation
using the
STATUS TAPE screen. When the ADD TAPE operation is complete,
the
STATUS TAPE screen will show In service, idle. Check the status of the
LEDs and State Exceptions.
27. For any upgrade (except when the release is already at R3.2) to work
correctly, the Transfer Dialplan information must be administered before
the first nightly backup. If this is not done, after the backup is run, the
DEFINITY AUDIX will not allow call transfer to work. Refer to the
DEFINITY
AUDIX System R3.2 Screens Reference,
585-300-211 for information on
administering this screen.
28. Run
DISPLAY TAPE to verify that the backup tape Software Release is now
Release 3.2.
29. If the administration alarm, A, appears on the status line, clear the alarm
by running
DISPLAY ADMINISTRATION-LOG and pressing (F3).
The administration alarm should now be gone from the status line. If the
command prompt fails to appear, press .
30. [5 min]
Run
SAVE NIGHTLY.
When the administration alarm, A, appears on the status line, run
DISPLAY
ADMINISTRATION-LOG
. If the SAVE NIGHTLY operation was successfully
completed,
save manual_nightly passed will be displayed.
RETURN
ENTER
CANCEL