7-10 Issue 1 September 1995
Circuit Card Replacement
!
WARNING:
Static electricity can be destructive to system parts. Use an antistatic wrist
strap whenever removing or installing a DEFINITY AUDIX system. Also use
an antistatic mat when servicing the MFB and alarm circuit cards.
Use this procedure if either, or both, the TN566B MFB and the TN2169 Alarm
Board must be replaced.
Step 1: Shut down the system in a camp-on manner using the Reset System
Shutdown
screen. The system will respond with information similar to the
following:
System name: audix
login:
INIT: New run level: 0
The system is coming down. Please wait.
System services are now being stopped.
System data saved during shutdown.
The system is down.
Transferring to Firmware.
.....
SHUTDOWN Pending, Code = F022
Software Maintenance Shutdown
SHUTDOWN Completed
Refer toFigure 7-1, Top View of DEFINITY AUDIX System; and to Figure 7-2, Side
View of DEFINITY AUDIX System; complete the steps below.
Figure 7-1. Top View of DEFINITY AUDIX System
SLOTTED SCREW RETAINING PINS SLOTTED SCREWS
MOUNTING BRACKET
I2C BUS CABLE
GANG LATCHES
SPRING CLIP