User guide
Task 23: Run Test Tape Long
Issue 1 September 1995
4-13
4. Retrieve the test Voice Mail message.
a. If you are in contact with someone at the remote site, ask them to
check the MWI — either a lamp on the phone or a stutter dial tone
— on the remote test subscriber’s phone. (The MWI signal may
take up to one minute to appear.) If it is on, proceed to the next
step. Otherwise, refer to the troubleshooting procedures in
DEFINITY AUDIX System—Maintenance
, 585-300-110.
b. Call the remote DEFINITY AUDIX extension to retrieve the
message. (If the remote switch is a System 85 or G2, this will be the
same number as for the local DEFINITY AUDIX System; for all other
remote switch types, the DEFINITY AUDIX extension for the remote
switch will be different from the extension for the local DEFINITY
AUDIX system.)
c. After the DEFINITY AUDIX system answers and prompts you for
your extension, enter the remote test subscriber’s extension and
press .
d. When prompted for your password, press the again.
e. Press then press to listen to the message you recorded.
f. After listening to the message, press to delete the message.
g. Hang up.
5. Send a Leave Word Calling (LWC) message to and from the remote test
subscriber. If possible, have someone check the MWI at the remote site.
6. Repeat Steps 1 through 5 for each DCS remote test subscriber.
7. Proceed to Task 23: Run Test Tape Long.
Task 23: Run Test Tape Long
This task is required for all installation scenarios.
At this point, the backup tape cartridge added in Task 16: Add Tape, should still
be in the tape drive.
1. Check the status of the tape drive and cartridge. With the cursor on the
DEFINITY AUDIX command line, enter status tape and press .
The system displays the Status Tape screen. The Status field should
display In service idle. If the Status field displays any other value,
see the Status Tape screen description in
DEFINITY AUDIX System —
R3.2 Screens Reference
, 585-300-212 for an explanation of the values of
the Status field or see
DEFINITY AUDIX System — Maintenance
,
585-300-110, for information on tape problems.
2. With the cursor on the DEFINITY AUDIX command line, enter test tape
long and press .
#
#
2 0
*
D
RETURN
RETURN