Specifications
3-12 Maintenance
6. Unscrew the retaining nut on the cable.
Figure 3-15 Stuffing Box
Figure 3-16 Joint
7. Unscrew the nut on the stuffing box and remove the joint.
8. Replace the resistor.
Figure 3-17 Remount Joint
Figure 3-18 Remount Mask
9. Remount joint in the stuffing box and tighten the screw.
CAUTION!
10. Mount the cable and lock the retaining nut on both connections.
To ensure proper positioning of the resistor, pull the resistor on the opposite side
of the vitro-ceramic glass while locking the screw of the stuffing box (up if you
change a resistor on the volt, down if it is on the plate).
11. Remount the mask and lock it with new plastic collars on both connections.
12. Repeat Steps 4 through 9 on the remaining resistor connection.
Resistor
Stuffing Box
Cable
Collars