Specifications
Maintenance 3-3
Maintenance Procedures
CAUTION!
Safety
Maintenance procedures should only be performed by trained service
technicians. Refer to the section for more information.
WARNING! Unless otherwise specified, the Cure Module should be shut down while
performing maintenance or troubleshooting procedures. Refer to “System
Shutdown” in the TC V3 Operations Manual.
Conveyor Torque Limiter Adjustment
To adjust the conveyor torque limiter:
1. Turn the power off by moving the Main Switch to the OFF position.
2. Remove the access cover at the output of the conveyor and set aside.
NOTE The torque limiter is mounted on the motor shaft, behind the motor ( ).
Figure 3-1 Torque Limiter Adjustment
3. Unscrew the latch-tightening screw with an Allen wrench ( ).
4. Adjust the limiter by turning the adjustment ring to allow space to turn the gear by hand.
5. Tighten the latch-tightening screw.
6. Turn the power back on by moving the Main Switch to the ON position.
7. Before starting a production, activate the conveyor movement. Make sure the gear on the
motor shaft does not slip.
8. Replace the access cover.
Allen Wrench
Gear
Torque Limiter
Latch-tightening
Screw
Adjustment Ring