User guide
Setup and Configuration 6-19
To perform a Valve Offsets procedure:
1. In the FMW Main Window, click on Configuration.
2. Click on Needle Setup, and select Setup Parameters.
3. In the Setup Parameters dialog box, shown in Figure 6-5, select Valve Offsets in the
Machine Setup Process section of the dialog box.
4. Click on OK.
?NOTE If you are changing from Calculate Master Offsets to Valve
Offsets, it is recommended that you exit FMW and restart FMW
before continuing this procedure.
5. Click on Needle Setup on the Configuration menu again, and select Valve Offsets.
> The Setup Valve Offsets dialog box, shown in Figure 6-6, opens.
Figure 6-6