6-12 Setup and Configuration
7. Lower the dispensing head until the needle is at the desired dispensing height.
> All subsequent dispensing operations will be performed at this height, including
dot and line parameter settings, except for ZFast dots.
8. Click on Next.
9. Follow the on-screen prompts for adjusting the probe height.
10. Click on Next.
11. Click on Done.
To perform Setup for No Height sense Mode (all three options):
1. Load a board or part into the dispensing area, if one is not already present.
?NOTE Since you are teaching the actual height of the dispensing
surface, you MUST use a board identical to one used in
production.
2. Use the position control buttons to lower the dispensing head so that it is just above
the substrate.
3. The location of the last height sense (if there was one) is displayed at the bottom of
the Teach window. If you choose to use the same measurement, click on GoTo, and
the dispensing head will move to that location.
4. Click on Teach.
> If you are running in Calculate Master Offsets mode, the dispensing head
performs a Find Needle XYZ procedure.
5. Click on Done to save the results.