User guide
9-10 Advanced Programming
50. Type in 30 seconds.
> The system will wait for 30 seconds before beginning the next run.
> Set the timer according to how long your fluid takes to underfill the flip chip
model.
51. Click on OK.
52. From the Program Commands toolbar, click on Dispensing Element.
53. Select Weight-Control Lines.
54. Enter 30 mg in the Total Weight text box and select Line Style 1.
55. Use the Position Controls to move the dispensing head to the ULHC of the first flip
chip in the ULHC of Pattern 1.
> Use Chip Offset or reticles.
56. Click on Teach.
57. Use the Position Controls to move the dispensing head to the LLHC of the same
flip chip.
> Use Chip Offset or reticles.
58. Click on Teach.
59. Use the Position Controls to move the dispensing head to the LRHC of the same
flip chip.
> Use Chip Offset or reticles.
60. Click on Teach.
61. Click on Done.
> A message box opens indicating the calculated line speed.
62. Click on OK.