User guide

Beginning Programming 8-11
24. Click on OK.
25. In the Programming Window, select Edit Line Parameters from the Edit menu to
open the Line Parameters dialog box.
26. Set the Line Parameters for Line Type 1 to:
Pre-Move Delay Factor: 0.1
Shut-off Distance: 0.010
Dispense Gap: 0.015
Speed: (not used for weight control lines)
Dwell: 0.0
Retract Distance: 0.100
Backtrack Gap: 0.050
Backtrack Length: 0.040
Backtrack Speed: 2
Down Speed: 2
Down Acceleration: 300
Retract Speed: 2
Retract Acceleration: 300
Suckback: 0.000
27. Click on Save.
28. In the Programming Window, select Dry Run from the Run menu.
> Watch to see the camera transverse the programmed lines. You may observe
a difference in dispensing speed for each line.
The dispensing head will move after your response.
If you get an error message that the speed is too slow, re-check your line
parameters and try again. Refer to Editing Lines earlier in this chapter.
29. In the Programming Window, select Wet Run from the Run menu.
> Watch as the lines are dispensed.
> Examine the board for quality and accuracy.
This concludes the tutorial on Weight Control Lines.