Service manual
AUX air conditioner service manual
61
Rated Cooling test condition Indoor unit: DB:27℃, WB:19℃ Outdoor unit: DB:35℃, WB:24℃
Max. Cooling test condition Indoor unit: DB:32℃, WB:23℃ Outdoor unit: DB:43℃, WB:26℃
4、Parameter for R22 、M Series、115V/60HZ products
ASW-09A3/M ASW-H09A3/M ASW-12B3/M ASW-H12B3/M
Model
Item
Indoor Outdoor Indoor Outdoor Indoor Outdoor Indoor Outdoor
Type Wall -mounted Wall -mounted Wall -mounted Wall -mounted
Cooling capacity Kw 2.6 2.6 3.5 3.5
Heating capacity Kw / 2.8 / 3.95
Dehumidifying Kg/h 0.77 0.77 1.1 1.1
Cooling m
3
/h 460 / 460 / 550 / 550 / Air
circulation
Heating m
3
/h / / 460 / / / 550 /
Cooling dB 39 52 39 52 42 52 42 52 Noise
lever
Heating dB / / 39 52 / / 42 52
Performance
Power-supply φ--V--Hz
1/115V/60Hz 1/115V/60Hz 1/115V/60Hz 1/115V/60Hz
Cooling W 920 920 1330 1330 Rated power
consumption
Heating W / 880 / 1360
Cooling A 8.0 8.0 11.6 11.6 Rated
current
Heating A / 7.7 / 11.9
Cooling % 98% 98% 98% Input
factor
Heating % / 98% / 98%
Starting current A 45 45 58 58
Length m / / / / / / / / Power supply
cord
Type / / / /
Input
Fuse capacity A 3.15 / 3.15 / 3.15 / 3.15 /
mm
180*82
0*280
320*81
8*540
180*82
0*280
320*81
8*540
180*82
0*280
320*81
8*540
180*82
0*280
320*81
8*540
Dimension D×W×H
Inch / / / / / / / /
Net weight Kg 10.5 30 10.5 31 11 33 11 35
Liquid(mm)
OD×L
φ6.35×3600 φ6.35×3600 φ6.35×3600 φ6.35×3600 Connection
pipe
Gas
(mm)
OD×L
φ9.52×3600 φ9.52×3600 φ12.7×3600 φ12.7×3600
Drain pipe (mm)
ID×L
φ14×780 φ14×780 φ14×780 φ14×780
Type / Rotary / Rotary / Rotary / Rotary
Type / / / / / / / /
Compresso
Motor
Rated input W / 877 / 877 / 1300 / 1300
Type
Throug
h-flow
Axial-fl
ow fan
Throug
h-flow
Axial-fl
ow fan
Throug
h-flow
Axial-fl
ow fan
Throug
h-flow
Axial-fl
ow fan
Type
Plastic-
sealed
Iron
shell
Plastic-
sealed
Iron
shell
Plastic-
sealed
Iron
shell
Plastic-
sealed
Iron
shell
Dimension
Fan-motor
Motor or
Rated input W 19 25 19 25 19 35 19 35
Heat exchanger (Row×line) 2×16 1×11 2×16 1×11 2×16 2×22 2×16 2×22
Refrigerant control Capillary Capillary Capillary Capillary
Freezed oil capacity / / / /
Refrigerant/Charge (g) R22/700 R22/790 R22/820 R22/1110
Protection equipment /
EXTERNAL
/
EXTERNAL
/
EXTERNAL
/
EXTERNAL
Rated Cooling test condition Indoor unit: DB:26.7℃, WB:19.4℃ Outdoor unit: DB:35℃, WB:23.9℃