Service manual
AUX air conditioner service manual
59
Refrigerant/Charge (g) R22/1050 R22/1290
Protection equipment / Inner / Inner
ASW-18B2/E# ASW-H18B2/E# ASW-24B2/E# ASW-H24B2/E#
Model
Item
Indoor Outdoor Indoor Outdoor Indoor Outdoor Indoor Outdoor
Type Wall -mounted Wall -mounted Wall -mounted Wall -mounted
Cooling capacity Kw 5.3 5.3 7.0 7.0
Heating capacity Kw / 5.8 / 7.7
Dehumidifying Kg/h 2.12 2.12 2.8 2.8
Cooling m
3
/h 850 / 850 / 1000 / 1000 / Air
circulation
Heating m
3
/h / / 900 / / / 1050 /
Cooling dB 50 57 50 57 49 57 49 57 Noise
lever
Heating dB / / 50 57 / / 49 571
Performance
Power-supply φ--V--Hz
1/208-230V/60Hz 1/208-230V/60Hz 1/208-230V/60Hz 1/208-230V/60Hz
Cooling W 1920 1950 2550 2550 Rated power
consumption
Heating W / 1900 / 2550
Cooling A 8.8 9.0 11.8 11.8 Rated
current
Heating A / 8.8 / 11.8
Cooling % 98% 98% 98% Input
factor
Heating % / 98% / 98%
Starting current A 45 45 59 59
Length m / / / / / / / / Power supply
cord
Type 250V 16A 250V 10A 250V 25A 250V 25A
Input
Fuse capacity A 3.15 / 3.15 / 3.15 / 3.15 /
mm
1095*2
05*312
800*30
0*690
1095*2
05*312
800*30
0*690
1095*2
05*312
800*30
0*690
1095*2
05*312
800*30
0*690
Dimension D×W×H
Inch / / / / / / / /
Net weight Kg 15 46 15 48 15 50 15 51
Liquid(mm)
OD×L
φ6.35×3600 φ6.35×3600 φ9.52×3600 φ9.52×3600 Connection
pipe
Gas
(mm)
OD×L
φ12.7×3600 φ12.7×3600 φ15.88×3600 φ15.88×3600
Drain pipe (mm)
ID×L
φ14×1100 φ14×1100 φ14×1100 φ14×1100
Type / Rotary / Rotary / Rotary / Rotary
Type / / / / / / / /
Compresso
Motor
Rated input W / 1990 / 1990 / 2425 / 2425
Type
Throug
h-flow
Axial-fl
ow fan
Throug
h-flow
Axial-fl
ow fan
Throug
h-flow
Axial-fl
ow fan
Throug
h-flow
Axial-fl
ow fan
Type
Plastic-
sealed
Iron
shell
Plastic-
sealed
Iron
shell
Plastic-
sealed
Iron
shell
Plastic-
sealed
Iron
shell
Dimension
Fan-motor
Motor or
Rated input W 20 68 20 68 30 68 30 68
Heat exchanger (Row×line) 2×13 2×30 2×13 2×30 2×16 2×26 2×16 2×26
Refrigerant control Capillary Capillary Capillary Capillary
Freezed oil capacity / / / /
Refrigerant/Charge (g) R22/1480 R22/1750 R22/1830 R22/2130
Protection equipment / Inner / Inner / Inner / Inner
Rated Cooling test condition Indoor unit: DB:27℃, WB:19℃ Outdoor unit: DB:35℃, WB:24℃