Motherboard Z8NR-D12
E4234 First Edition V1 January 2009 Copyright © 2009 ASUSTeK COMPUTER INC. All Rights Reserved. No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval system, or translated into any language in any form or by any means, except documentation kept by the purchaser for backup purposes, without the express written permission of ASUSTeK COMPUTER INC. (“ASUS”).
Contents Contents....................................................................................................... iii Notices......................................................................................................... vii Safety information..................................................................................... viii About this guide.......................................................................................... ix Z8NR-D12 specifications summary...................
Contents 2.5.7 PIKE slot........................................................................ 2-16 2.5.9 Installing i Button............................................................ 2-17 2.5.8 2.6 2.7 Jumpers....................................................................................... 2-18 Connectors.................................................................................. 2-23 2.7.1 2.7.2 Chatper 3: 3.1 3.2 3.2.1 4.1.1 4.1.2 Using the OS shut down function..................
Contents 4.4 Advanced menu.......................................................................... 4-13 4.4.1 CPU Configuration......................................................... 4-13 4.4.3 Legacy Device Configuration......................................... 4-20 4.4.2 4.4.4 4.4.5 4.4.6 4.4.7 4.4.8 4.4.9 4.5 4.6 4.4.10 Power On Configuration................................................. 4-22 Event Log Configuration................................................ 4-23 Hardware Monitor......
Contents 5.3 Intel® Matrix Storage Manager Option ROM Utility.................. 5-23 5.3.1 Creating a RAID set....................................................... 5-24 5.3.3 Deleting a RAID set....................................................... 5-27 5.3.2 5.3.4 5.3.5 5.3.6 5.3.7 5.3.8 Chapter 6: 6.1 6.2 6.3 6.4 6.5 6.1.1 6.1.2 Recovery Volume Options............................................. 5-29 Exiting the Intel® Matrix Storage Manager..................... 5-30 Rebuilding the RAID......
Notices Federal Communications Commission Statement This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: • • This device may not cause harmful interference, and This device must accept any interference received including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Safety information Electrical safety • • • • • • To prevent electrical shock hazard, disconnect the power cable from the electrical outlet before relocating the system. When adding or removing devices to or from the system, ensure that the power cables for the devices are unplugged before the signal cables are connected. If possible, disconnect all power cables from the existing system before you add a device.
About this guide This user guide contains the information you need when installing and configuring the motherboard. How this guide is organized This user guide contains the following parts: • • • • • Chapter 1: Product introduction This chapter describes the features of the motherboard and the new technologies it supports. Chapter 2: Hardware information This chapter lists the hardware setup procedures that you have to perform when installing system components.
Conventions used in this guide To make sure that you perform certain tasks properly, take note of the following symbols used throughout this manual. DANGER/WARNING: Information to prevent injury to yourself when trying to complete a task. CAUTION: Information to prevent damage to the components when trying to complete a task. IMPORTANT: Instructions that you MUST follow to complete a task. NOTE: Tips and additional information to help you complete a task.
Z8NR-D12 specifications summary Model Name Processor / System Bus Core Logic Form Factor ASUS Features Memory Smart Fan Rack Ready (Rack and Pedestal dual use) Rack Optimized (Dedicated for Rack) ASWM PIKE Flex-E Total Slots Capacity Memory Type Expansion Slots (follow SSI Location #) Storage Memory Size Total PCI/PCI-X/PCI-E Slots Slot Location 1 Slot Location 3 Slot Location 4 Slot Location 5 Slot Location 6 Additional Slot SATA Controller SAS Controller Z8NR-D12 2 x Socket LGA1366 Quad-Core Intel
Z8NR-D12 specifications summary Networking Graphic Onboard I/O Connectors Rear I/O Connectors Management Solution Monitoring Environment LAN VGA PSU Connector USB Connectors Fan Header SMBus Chassis Intruder Front LAN LED Serial Port Header External Serial Port External USB Port VGA Port RJ-45 PS/2 KB/Mouse Software Out of Band Remote Management CPU Temperature FAN RPM 2 x Intel® 82574L + 1 x Management LAN Aspeed AST2050 8MB 24-pin ATX power connector + 2 x 8-pin ATX 12V power connector 3 (support 4 US
This chapter describes the motherboard features and the new technologies it supports.
1 Chapter summary 1.1 Welcome!....................................................................................... 1-1 1.3 Serial number label....................................................................... 1-2 1.2 1.4 Package contents.......................................................................... 1-1 Special features.............................................................................
1.1 Welcome! Thank you for buying an ASUS® Z8NR-D12 motherboard! The motherboard delivers a host of new features and latest technologies, making it another standout in the long line of ASUS quality motherboards! Before you start installing the motherboard, and hardware devices on it, check the items in your package with the list below. 1.2 Package contents Check your motherboard package for the following items.
1.3 Serial number label Before requesting support from the ASUS Technical Support team, you must take note of the motherboard's serial number containing 12 characters xxM0Axxxxxxx shown as the figure below. With the correct serial number of the product, ASUS Technical Support team members can then offer a quicker and satisfying solution to your problems. Z8NR-D12 xxM0Axxxxxxx 1.4 Special features 1.4.
Intel® EM64T The motherboard supports Intel® processors with the Intel® EM64T (Extended Memory 64 Technology). The Intel® EM64T feature allows your computer to run on 64-bit operating systems and access larger amounts of system memory for faster and more efficient computing. PCIe 2.0 This motherboard supports the latest PCIe 2.0 device for twice the current speed and bandwidth. This enhances system performance while still providing backward compatibility to PCIe 1.0 devices.
Temperature, fan, and voltage monitoring The CPU temperature is monitored by the W83795AG chip to prevent overheating and damage. The system fan rotations per minute (RPM) is monitored for timely failure detection. The chip monitors the voltage levels to ensure stable supply of current for critical components. 1.4.
This chapter lists the hardware setup procedures that you have to perform when installing system components. It includes description of the jumpers and connectors on the motherboard.
Chapter summary 2 2.1 Before you proceed...................................................................... 2-1 2.3 Central Processing Unit (CPU).................................................... 2-6 2.2 2.4 2.5 2.6 2.7 Motherboard overview.................................................................. 2-2 System memory.......................................................................... 2-11 Expansion slots...........................................................................
2.1 Before you proceed Take note of the following precautions before you install motherboard components or change any motherboard settings. • Unplug the power cord from the wall socket before touching any component. • Use a grounded wrist strap or touch a safely grounded object or a metal object, such as the power supply case, before handling components to avoid damaging them due to static electricity. • Hold components by the edges to avoid touching the ICs on them.
2.2 Motherboard overview Before you install the motherboard, study the configuration of your chassis to ensure that the motherboard fits into it. To optimize the motherboard features, we highly recommend that you install it in an SSI EEB compliant chassis. Ensure to unplug the chassis power cord before installing or removing the motherboard. Failure to do so can cause you physical injury and damage motherboard components! 2.2.
2.2.
2.2.4 Layout contents Slots / Sockets Page 1. CPU sockets 2-6 2. DDR3 DIMM sockets 2-11 3. PCI Express x16 slot (x16 link) 2-16 4. PCI Express x8 slots (x8 link; x4 link) 2-16 5. PCI slot 2-16 6. PIKE slot 2-16 Jumpers 2-4 Page 1. Clear RTC RAM (CLRTC1) 2-18 2. VGA controller setting (3-pin VGA_SW1) 2-19 3. LAN controller setting (3-pin LAN_SW1, LAN_SW2) 2-19 4. iBTN RAID setting (3-pin IBTN_SEL1) 2-20 5. RAID configuration utility selection (3-pin RAID_SEL1) 2-20 6.
Internal connectors Page 1. Floppy disk drive connector (34-1 pin FLOPPY1) 2-24 2. Serial ATA connectors (7-pin SATA1–4 [red], SATA5–6 [black]) 2-24 3. SAS connectors (7-pin SAS1–4 [red], SAS5–8 [blue]) 2-25 4. Hard disk activity LED connector (4-pin HDLED1) 2-25 5. Serial General Purpose Input/Output connector (6-1 pin SGPIO1) 2-26 6. Serial General Purpose Input/Output connectors (6-1 pin SGPIO2/3) 2-26 7. USB connectors (10-1 pin USB34, USB56; 4-pin USB7) 2-27 8.
2.3 Central Processing Unit (CPU) The motherboard comes with two surface mount LGA1366 sockets designed for the Intel® Xeon® Dual/Quad Core processor. 2.3.1 • Your boxed Intel® Xeon® LGA1366 processor package should come with installation instructions for the CPU and heatsink. If the instructions in this section do not match the CPU documentation, follow the latter. • Upon purchase of the motherboard, ensure that the PnP cap is on the socket and the socket contacts are not bent.
2. Press the load lever with your thumb (A), then move it to the left (B) until it is released from the retention tab. To prevent damage to the socket pins, do not remove the PnP cap unless you are installing a CPU. 3. 4. Retention tab A B Load lever Lift the load lever in the direction of the arrow to a 135º angle. Load plate Lift the load plate with your thumb and forefinger to a 100º angle. 4 3 5. Remove the PnP cap from the CPU socket.
6. Position the CPU over the socket, ensuring that the gold triangle is on the bottom‑left corner of the socket, and then fit the socket alignment key into the CPU notch. The CPU fits in only one correct orientation. DO NOT force the CPU into the socket to prevent bending the connectors on the socket and damaging the CPU! Gold triangle mark CPU notch Alignment key 7.
2.3.2 Installing the CPU heatsink and fan The Intel Xeon™ processors require an Intel certified heatsink and fan assembly to ensure optimum thermal condition and performance. ® When you buy a boxed Intel CPU, the package includes the heatsink, fan, retention brackets, screws, thermal grease, installation manual, and other items that are necessary for CPU installation. • Ensure that you have applied the thermal grease to the top of the CPU before installing the heatsink and fan.
3. Connect the fan cable to the nearest 4‑pin fan connector. FAN connector DO NOT forget to connect the CPU fan cable! Hardware monitoring errors may occur if you fail to plug this connector. 4. 2-10 Repeat steps 1 to 3 to install the other heatsink if you have installed a second CPU, then connect the fan cable to the nearest 4‑pin fan connector.
2.4 System memory 2.4.1 Overview The motherboard comes with twelve (12) Double Data Rate 3 (DDR3) Dual Inline Memory Modules (DIMM) sockets.
2.4.2 Memory configurations You may install 512 MB, 1 GB, 2 GB, 4 GB and 8GB registered DIMMs or Unbuffered DIMM with ECC / non- ECC into the DIMM sockets. 2-12 • Always install DIMMs with the same CAS latency. For optimum compatibility, we recommend that you obtain memory modules from the same vendor. Refer to the Qualified Vendors List on the ASUS web site. • You may install varying memory sizes in Channel A, Channel B and Channel C.
2.4.3 Installing a DIMM Ensure to unplug the power supply before adding or removing DIMMs or other system components. Failure to do so may cause severe damage to both the motherboard and the components. 1. 2. 2 Unlock a DIMM socket by pressing the retaining clips outward. DIMM notch Align a DIMM on the socket such that the notch on the DIMM matches the break on the socket. 1 1 Unlocked retaining clip A DIMM is keyed with a notch so that it fits in only one direction.
2.5 Expansion slots In the future, you may need to install expansion cards. The following sub‑sections describe the slots and the expansion cards that they support. Ensure to unplug the power cord before adding or removing expansion cards. Failure to do so may cause you physical injury and damage motherboard components. 2.5.1 Installing an expansion card To install an expansion card: 1. 2. 3. 4. 5. 6.
2.5.
2.5.4 PCI Express x16 slot (x16 link) The onboard PCI Express x16 slots provides x16 link to the 5500 IOH. This slot supports VGA cards and various server class high performance add-on cards. The slot switches to x8 link automatically if the slot location 5 is occupied. 2.5.5 PCI Express x8 slots (x8 link; x4 link) The onboard PCI Express x8 andd x4 slots provide x8 link and x4 link to the 5500 IOH.
2.5.8 Installing ASUS PIKE RAID card Follow the steps below to install an optional ASUS RAID card on your motherboard. 1. Locate the PIKE RAID card slot on the motherboard. 2. Align the golden fingers of the RAID card with the PIKE RAID card slot. 3. Insert the RAID card into the PIKE RAID card slot. Ensure that it is completely seated on the PIKE RAID card slot. 2.5.9 Installing i Button Follow the steps below to install an optional i Button on your motherboard. 1.
2.6 1. Jumpers Clear RTC RAM (CLRTC1) This jumper allows you to clear the Real Time Clock (RTC) RAM in CMOS. You can clear the CMOS memory of date, time, and system setup parameters by erasing the CMOS RTC RAM data. The onboard button cell battery powers the RAM data in CMOS, which include system setup information such as system passwords. To erase the RTC RAM: 1. 2. 3. 4. Turn OFF the computer and unplug the power cord. Move the jumper cap from pins 1–2 (default) to pins 2–3.
2. 3. VGA controller setting (3-pin VGA_SW1) This jumper allows you to enable or disable the onboard VGA controller. Set to pins 1–2 to activate the VGA feature. LAN controller setting (3-pin LAN_SW1, LAN_SW2) These jumpers allow you to enable or disable the onboard Intel® WG82574L Gigabit LAN1/2 controller. Set to pins 1–2 to activate the Gigabit LAN feature.
4. 5. 2-20 iBTN RAID setting (3-pin IBTN_SEL1) This jumper allows you to select the RAID configuration utility to use when you create disk arrays. Place the jumper caps on pins 1–2 if you install a PIKE RAID card to the motherboard and want to use the LSI Logic MPT Setup Utility (default). Or you can place the jumper caps on pins 2–3 to create the LSI Mega RAID 5 by supported Intel® ICH10R SATA controller. • LSI Logic MPT Setup Utility is available only when you install a PIKE RAID card.
6. Force BIOS recovery setting (3-pin RECOVERY1) This jumper allows you to quickly update or recover the BIOS settings when it becomes corrupted. To update the BIOS: 1. 2. 3. 4. 5. 6. Prepare a floppy disk that contains the original or latest BIOS for the motherboard (XXXXXX.ROM) and the AFUDOS.EXE utility. Set the jumper to pins 2–3. Insert the floppy disk then turn on the system to update the BIOS. Shut down the system. Set the jumper back to pins 1–2. Turn on the system.
7. 8. 2-22 Fan control setting (3-pin FAN_SEL1) This jumper allows you to switch for fan pin selection. Set to pins 1–2 when using 4-pin fans or pins 2–3 when using 3-pin fans. • If you use a 4-pin fan but set the jumper to pin 2-3, the fan you installed may not work. • If you use a 3-pin fan but set the jumper for a 4-pin fan, the fan controll will not work and the fan you installed will always run at full speed.
2.7 Connectors 2.7.1 Rear panel connectors 1. 2. 3. 4. 5. 6. 7. 8. PS/2 mouse port (green). This port is for a PS/2 mouse. RJ-45 port for iKVM. This RJ-45 port functions only when you install the ASUS ASMB4 iKVM management card. PS/2 keyboard port (purple). This port is for a PS/2 keyboard. USB 2.0 ports 1 and 2. These two 4-pin Universal Serial Bus (USB) ports are available for connecting USB 2.0 devices. Serial (COM1) port.
2.7.2 1. Internal connectors Floppy disk drive connector (34-1 pin FLOPPY1) This connector is for the floppy disk drive (FDD) signal cable. Insert one end of the cable to this connector, then connect the other end to the signal connector at the back of the floppy disk drive. Pin 5 on the connector is removed to prevent incorrect cable connection when using a FDD cable with a covered Pin 5. 2.
3. 4. SAS connectors (7-pin SAS1–4 [red]; 7-pin SAS5–8 [blue]) This motherboard comes with eight (8) Serial Attached SCSI (SAS) connectors, the next-generation storage technology that supports both Series SCSI and Serial ATA (SATA). Each connector supports one device. • These connectors function only when you install a PIKE RAID card. • Connect the SAS hard disk drives to SAS connectors 1–4 (red) when installing a 4-port PIKE RAID card.
5. 6. Serial General Purpose Input/Output connector (6-1 pin SGPIO1) This connector is used for the SGPIO peripherals for the LSI embedded SATA RAID or Intel Matrix RAID. Serial General Purpose Input/Output connectors (6-1 pin SGPIO2/3) These connector is used for the SAS chip SIO interface that controls the LED pattern generation, device information and general purpose data. These connectors functions only when you install a PIKE SAS RAID card.
7. USB connectors (10-1 pin USB34, USB56; 4-pin USB7) The USB34 and USB56 connectors are for USB 2.0 ports. Connect the USB module cable to the connectors, and then install the module to a slot opening at the back of the system chassis. The USB7 connector is for a A-type internal USB 2.0 device. The USB connectors comply with USB 2.0 specification that supports up to 480 Mbps connection speed. The USB port module is purchased separately. 8.
9. Serial port connector (10-1 pin COM2) This connector is for a serial (COM) port. Connect the serial port module cable to this connector, then install the module to a slot opening at the back of the system chassis. The serial port module is purchased separately. 10. Power supply SMBus connector (5-pin PSUSMB1) This connector is for the power supply SMB cable, if your power supply supports the SMBus function.
11. SSI power connectors (24-pin ATXPWR1, 8-pin ATX12V1/2) These connectors are for SSI power supply plugs. The power supply plugs are designed to fit these connectors in only one orientation. Find the proper orientation and push down firmly until the connectors completely fit. • • • • For a fully configured system, we recommend that you use an SSI 12 V-compliant power supply unit (PSU) for LGA1366‑socket Intel® Xeon processors.
13. System panel connector (20-pin PANEL1 [white]) This connector supports several chassis-mounted functions. 1. 2. 3. 4. 5. 6. 2-30 System power LED (3-pin PLED) This 3-pin connector is for the system power LED. Connect the chassis power LED cable to this connector. The system power LED lights up when you turn on the system power, and blinks when the system is in sleep mode. Message LED (2-pin MLED) This 2-pin connector is for the message LED cable that connects to the front message LED.
14. Auxiliary panel connector (20-pin AUX_PANEL1 [black]) This connector is for additional front panel features including front panel SMB, locator LED and switch, chassis intrusion, and LAN LEDs. 1. 2. 3. 4. 5. Front panel SMB (6-1 pin FPSMB) These leads connect the front panel SMBus cable. LAN activity LED (2-pin LAN1_LED, LAN2_LED) These leads are for Gigabit LAN activity LEDs on the front panel.
2-32 Chapter 2: Hardware information
This chapter describes the power up sequence, and ways of shutting down the system.
Chapter summary 3.1 3.2 3 Starting up for the first time......................................................... 3-1 Turning off the computer..............................................................
3.1 Starting up for the first time 1. After making all the connections, replace the system case cover. 3. Connect the power cord to the power connector at the back of the system chassis. 2. 4. 5. 6. Be sure that all switches are off. Connect the power cord to a power outlet that is equipped with a surge protector. Turn on the devices in the following order: a. Monitor b. System power After applying power, the system power LED on the system front panel case lights up.
3.2 Turning off the computer 3.2.1 Using the OS shut down function If you are using Windows® 2003: 1. 2. 3. Click the Start button then click Shut Down... Ensure that the Shut Down option button is selected, then click the OK button to shut down the computer. The power supply should turn off after Windows® shuts down. If you are using Windows® XP: 1. Click the Start button then select Turn Off Computer. 3. The power supply should turn off after Windows® shuts down. 2.
This chapter tells how to change the system settings through the BIOS Setup menus. Detailed descriptions of the BIOS parameters are also provided.
Chapter summary 4 4.1 Managing and updating your BIOS............................................. 4-1 4.3 Main menu..................................................................................... 4-7 4.2 4.4 4.5 4.6 4.7 BIOS setup program..................................................................... 4-4 Advanced menu.......................................................................... 4-13 Server menu................................................................................
4.1 Managing and updating your BIOS The following utilities allow you to manage and update the motherboard Basic Input/Output System (BIOS) setup: 1. 2. AFUDOS utility (Updates the BIOS in DOS mode using a bootable USB flash drive.) ASUS CrashFree BIOS 3 (To recover the BIOS using a USB flash drive when the BIOS file fails or gets corrupted.) Refer to the corresponding sections for details on these utilities.
Updating the BIOS file To update the BIOS file using the AFUDOS utility: 1. Visit the ASUS website (www.asus.com) and download the latest BIOS file for the motherboard. Save the BIOS file to a bootable USB flash drive. Write the BIOS filename on a piece of paper. You need to type the exact BIOS filename at the DOS prompt. 2. 3. Copy the AFUDOS utility (afudos.exe) from the motherboard support CD to the bootable USB flash drive.
4.1.2 ASUS CrashFree BIOS 3 utility The ASUS CrashFree BIOS 3 is an auto recovery tool that allows you to restore the BIOS file when it fails or gets corrupted during the updating process. You can update a corrupted BIOS file using a USB flash drive that contains the updated BIOS file. Prepare a USB flash drive containing the updated motherboard BIOS before using this utility. To recover the BIOS using ASUS CrashFree BIOS 3 1. Insert the USB flash disk that contains the BIOS file to the USB port. 3.
4.2 BIOS setup program This motherboard supports a programmable firmware chip that you can update using the provided utility described in section 4.1 Managing and updating your BIOS. Use the BIOS Setup program when you are installing a motherboard, reconfiguring your system, or prompted to “Run Setup.” This section explains how to configure your system using this utility. Even if you are not prompted to use the Setup program, you can change the configuration of your computer in the future.
4.2.1 BIOS menu screen Menu items Main Menu bar Advanced Configuration fields Server System Time System Date Legacy Diskette A SATA SATA SATA SATA SATA SATA 1 2 3 4 5 6 : : : : : : General help BIOS SETUP UTILITY Boot Exit [13:44:30] [Tue, 11/04/2008] [1.44M, 3.5 in.] Use [ENTER], [TAB] or [SHIFT-TAB] to select a field. [ST3160812AS] [Not Detected] [Not Detected] [Not Detected] [Not Detected] [TSSTcorp CDDVDW TS] Use [+] or [-] to configure system Date.
4.2.4 Menu items The highlighted item on the menu bar displays the specific items for that menu. For example, selecting Main shows the Main menu items. The other items (Advanced, Power, Boot, and Exit) on the menu bar have their respective menu items. 4.2.5 Sub-menu items A solid triangle before each item on any menu screen means that the item has a sub-menu. To display the sub-menu, select the item and press . 4.2.6 Configuration fields These fields show the values for the menu items.
4.3 Main menu When you enter the BIOS Setup program, the Main menu screen appears, giving you an overview of the basic system information. Refer to section 4.2.1 BIOS menu screen for information on the menu screen items and how to navigate through them. Main Advanced Server System Time System Date Legacy Diskette A SATA SATA SATA SATA SATA SATA 1 2 3 4 5 6 : : : : : : BIOS SETUP UTILITY Boot Exit [13:44:30] [Tue, 11/04/2008] [1.44M, 3.5 in.
4.3.4 SATA1–6 The BIOS automatically detects the connected IDE devices. There is a separate sub-menu for each IDE device. Select a device item, then press to display the IDE device information. BIOS SETUP UTILITY Main Select the type of device connected to the system. SATA 1 Device :Hard Disk Vendor :ST3160812AS Size :160.0GB LBA Mode :Supported Block Mode:16Sectors PIO Mode :4 Async DMA :MultiWord DMA-2 Ultra DMA :Ultra DMA-6 S.M.A.R.T.
PIO Mode [Auto] Allows you to select the data transfer mode. Configuration options: [Auto] [0] [1] [2] [3] [4] DMA Mode [Auto] Sets the DMA mode. Configuration options: [Auto] [SWDMA0] [SWDMA1] [SWDMA2] [MWDMA0] [MWDMA1] [MWDMA2] [UDMA0] [UDMA1] [UDMA2] [UDMA3] [UDMA4] [UDMA5] S.M.A.R.T. [Auto] Sets the Smart Monitoring, Analysis, and Reporting Technology. Configuration options: [Auto] [Disabled] [Enabled] 32Bit Data Transfer [Enabled] Enables or disables 32-bit data transfer.
4.3.5 IDE Configuration The items in this menu allow you to set or change the configurations for the IDE devices installed in the system. Select an item then press if you wish to configure the item.
4.3.6 AHCI Configuration This menu is the section for AHCI configuration. BIOS SETUP UTILITY Main AHCI Settings AHCI CD/DVD Boot Time out SATA SATA SATA SATA SATA SATA Port1 Port2 Port3 Port4 Port5 Port6 [Not [Not [Not [Not [Not [Not [35] Some SATA CD/DVD in AHCI mode need to wait ready longer. Detected] Detected] Detected] Detected] Detected] Detected] AHCI CD/DVD Boot Time out [35] Selects the boot time out value for SATA CD/DVD devices in AHCI mode.
4.3.7 System Information This menu gives you an overview of the general system specifications. The BIOS automatically detects the items in this menu. Main BIOS SETUP UTILITY AMIBIOS Version : 0208 Build Date: 12/09/08 Processor Speed : 2666MHz Count : 1 System Memory Usable Size : 1023MB System Memory Information AMIBIOS Displays the auto-detected BIOS information. Processor Displays the auto-detected CPU specification. System Memory Displays the auto-detected system memory.
4.4 Advanced menu The Advanced menu items allow you to change the settings for the CPU and other system devices. Take caution when changing the settings of the Advanced menu items. Incorrect field values can cause the system to malfunction.
Ratio CMOS Setting [Auto] Allows you to adjust the ratio between CPU Core Clock and BCLK Frequency. Use the <+> and <-> keys to adjust the value. Configuration options: [Auto] [12.0] [13.0] [14.0] [15.0] [16.0] [17.0] [18.0] [19.0] [20.0] C1E Support [Enabled] Allows you to enable or disable Enhanced Halt State support. Configuration options: [Disabled] [Enabled] Hardware Prefetcher [Enabled] Allows you to enable or disable the Hardware Prefetcher function.
A20M [Disabled] Legacy OSes and APs may need A20M enabled. Configuration options: [Disabled] [Enabled] DCU Mode [32KB 8-way without ECC] Select the mode for the Data Cache. Configuration options: [32KB 8-way without ECC] [16KB 4-way with ECC] DCA Prefetch Delay [32] This programs the time delay in bus clocks from snoop to prefetch.
C3 Auto Demotion [Enabled] When enabled, CPU will conditionally demote C6/C7 requests to C3 based on oncore auto-demote information. Configuration options: [Disabled] [Enabled] 4.4.2 Chipset Configuration The Chipset configuration menu allows you to change advanced chipset settings. Select an item then press to display the sub-menu. BIOS SETUP UTILITY Advanced Advanced Chipset Settings WARNING: Setting wrong values in below sections may cause system to malfunction.
CSI Links Speed [Full-Speed] Allows you to set the speed of CSI Links. Configuration options: [Slow-Mode] [Full-Speed] CSI Frequency [Auto] Allows you to set the CSI frequency. Configuration options: [Auto] [4.800GT] [5.866GT] [6.
Page Policy [Closed] Configuration options: [Closed] [Open] Adaptive Page [Disabled] Configuration options: [Disabled] [Enabled] Data Scramble [Enabled] Configuration options: [Disabled] [Enabled] Split Below 4GB [Disabled] Configuration options: [Disabled] [Auto] Channel Interleaving [6:1] Configuration options: [1:1] [2:1] [4:1] [6:1] Rank Interleaving [4:1] Configuration options: [1:1] [2:1] [4:1] North Bridge Chipset Configuration BIOS SETUP UTILITY Advanced NorthBridge Chipset Configurati
USB Functions [7 USB Ports] Allows you to configure the amount of USB ports to be enabled. Configuration options: [Disabled] [2 USB Ports] [4 USB Ports] [6 USB Ports] [7 USB Ports] USB Port Configure [6+6 USB Ports] Configuration options: [6+6 USB Ports] [8+4 USB Ports] USB 2.0 Controller [Enabled] Allows you to enable or disable the USB 2.0 controller. This item cannot be configurable if you set the USB Functions item to [7 USB Ports].
4.4.3 Legacy Device Configuration Advanced BIOS SETUP UTILITY Legacy Device Configuration Onboard Floppy Controller Serial Port1 Address Serial Port2 Address [Enabled] [3F8/IRQ4] [2F8/IRQ3] Allows BIOS to Enable or Disable Floppy Controller. Onboard Floppy Controller [Enabled] Allows you to enable or disable the onboard floppy controller. Configuration options: [Disabled] [Enabled] Serial Port1 Address [3F8/IRQ4] Allows you to select the Serial Port1 base address.
BIOS EHCI Hand-Off [Enabled] Enables or disables the BIOS EHCI hand-off support. Configuration options: [Disabled] [Enabled] Hotplug USB FDD Support [Auto] Allows you to configure the Hotplug USB FDD support. Configuration options: [Disabled] [Enabled] [Auto] 4.4.5 PCIPnP The PCIPnP menu items allow you to change the advanced settings for PCI/PnP devices. Take caution when changing the settings of the PCI/PnP Configuration menu items. Incorrect field values can cause the system to malfunction.
4.4.6 Power On Configuration Advanced BIOS SETUP UTILITY APM Configuration Options Restore on AC Power Loss [Last State] Resume On Ring Resume On PME#(Wake On LAN) Resume On RTC Alarm [Disabled] [Disabled] [Disabled] Power Off Power On Last State ←→ ↑↓ +F1 F10 ESC Select Screen Select Item Change Option General Help Save and Exit Exit v02.61 (C)Copyright 1985-2008, American Megatrends, Inc.
4.4.7 Event Log Configuration Advanced Event Logging details View Event Log Mark all events as read Clear Event Log BIOS SETUP UTILITY View all unread events on the Event log. ←→ ↑↓ Enter F1 F10 ESC Select Screen Select Item Go to Sub Screen General Help Save and Exit Exit v02.61 (C)Copyright 1985-2008, American Megatrends, Inc. View Event Log Press the key to view unread system event log. Make all events as read Press the key to mark all events as read.
4.4.8 Hardware Monitor Advanced Hardware Monitor CPU1 Temperature CPU2 Temperature Front Fan1 Speed Front Fan2 Speed Front Fan3 Speed Front Fan4 Speed Front Fan5 Speed Front Fan6 Speed Rear Fan1 Speed Rear Fan2 Speed Smart Fan Control VCORE1 Voltage VCORE2 Voltage +1.5V_P1DDR3 Voltage +1.5V_P2DDR3 Voltage +1.5V_ICH Voltage P1VTT Voltage P2VTT Voltage v02.61 (C)Copyright BIOS SETUP UTILITY CPU1 Temperature [41.5ºC/106.
4.4.9 ACPI Configuration BIOS SETUP UTILITY Advanced ACPI Settings Advanced ACPI Configuration settings. Advanced ACPI Configuration Chipset ACPI Configuration General WHEA Configuration Use this section to configure additional ACPI options. Advanced ACPI Configuration Advanced BIOS SETUP UTILITY Advanced ACPI Configuration ACPI 2.0 Support ACPI APIC support BIOS-->AML ACPI table Headless mode [Enabled] [Enabled] [Enabled] [Disabled] Add additional tables as per ACPI 2.0 specifications.
Energy Lake Feature [Disabled] Allows you to enable or disable the Energy Lake feature. Configuration options: [Enabled] [Disabled] APIC ACPI SCI IRQ [Disabled] Allows you to enable or disable the APIC ACPI SCI IRQ feature. Configuration options: [Disabled] [Enabled] USB Device Wakeup From S3/S4 [Disabled] Allows you to enable or disable the USB device wakeup from S3/S4 feature.
4.5 Server menu The Server menu items allow you to customize the server features. Main Advanced BIOS SETUP UTILITY Boot Exit Server Configure Remote Access. Remote Access Configuration ←→ ↑↓ Enter F1 F10 ESC Select Screen Select Item Go to Sub Screen General Help Save and Exit Exit v02.61 (C)Copyright 1985-2008, American Megatrends, Inc. Remote Access Configuration The items in this menu allows you to configure the Remote Access features.
Serial port Mode [57600 8,n,1] Sets the Serial port mode. Configuration options: [115200 8,n,1] [57600 8,n,1] [38400 8,n,1] [19200 8,n,1] [09600 8,n,1] Flow Control [Hardware] Allows you to select the flow control for console redirection. Configuration options: [None] [Hardware] [Software] Redirection After BIOS POST [Disabled] Sets the redirection mode after the BIOS Power-On Self-Test (POST). Some operating system may not work when set to [Always].
4.6 Boot menu The Boot menu items allow you to change the system boot options. Select an item then press to display the sub-menu. Main Advanced BIOS SETUP UTILITY Boot Exit Server Specifies the Boot Device Priority sequence. Boot Settings Boot Device Priority Hard Disk Drives Removable Drives A virtual floppy disk drive (Floppy Drive B: ) may appear when you set the CD-ROM drive as the first boot device.
4.6.2 Hard Disk Drives BIOS SETUP UTILITY Boot Hard Disk Drives 1st Boot Device 2nd Boot Device [SATA:SS-ST3160812A] [USB:JetFlash TS256] Specifies the boot sequence from the available devices. ←→ ↑↓ +F1 F10 ESC Select Screen Select Item Change Option General Help Save and Exit Exit v02.61 (C)Copyright 1985-2008, American Megatrends, Inc. 1st ~ xxth Drive [XXXXXXX] These items specify the boot device priority sequence from the available hard disk devices.
4.6.4 Boot Settings Configuration BIOS SETUP UTILITY Boot Boot Settings Configuration Quick Boot Full Screen Logo AddOn ROM Display Mode Bootup Num-Lock Wait For ‘F1‘ If Error Hit ‘DEL‘ Message Display Interrupt 19 Capture [Enabled] [Enabled] [Force BIOS] [On] [Enabled] [Enabled] [Enabled] Allows BIOS to skip certain tests while booting. This will decrease the time needed to boot the system. ←→ ↑↓ +F1 F10 ESC Select Screen Select Item Change Option General Help Save and Exit Exit v02.
4.6.5 Security The Security menu items allow you to change the system security settings. Select an item then press to display the configuration options. BIOS SETUP UTILITY Boot Security Settings Supervisor Password : Not Installed User Password : Not Installed to change password. again to disable password. Change Supervisor Password Change User Password ←→ ↑↓ Enter F1 F10 ESC Select Screen Select Item Change General Help Save and Exit Exit v02.
After you have set a supervisor password, the other items appear to allow you to change other security settings. Main Advanced Server BIOS SETUP UTILITY Power Boot Tools Supervisor Password : Installed User Password : Not Installed Change Supervisor Password User Access Level Change User Password Password Check [Full Access] Exit to change password. again to disable password.
4.7 Exit menu The Exit menu items allow you to load the optimal or failsafe default values for the BIOS items, and save or discard your changes to the BIOS items. Main Advanced Server Exit Options Exit & Save Changes Exit & Discard Changes Discard Changes Load Setup Defaults BIOS SETUP UTILITY Boot Exit Exit system setup after saving the changes. F10 key can be used for this operation. ←→ ↑↓ Enter F1 F10 ESC Select Screen Select Item Go to Sub Screen General Help Save and Exit Exit v02.
This chapter provides instructions for setting up, creating, and configuring RAID sets using the available utilities.
Chapter summary 5 5.1 Setting up RAID............................................................................. 5-1 5.3 Intel® Matrix Storage Manager Option ROM Utility.................. 5-23 5.2 LSI Software RAID Configuration Utility.....................................
5.1 Setting up RAID The motherboard comes with the Intel® ICH10R southbridge controller that supports the following SATA RAID solutions: • • LSI Software RAID Configuration Utility (default) with RAID 0, RAID 1, and RAID 10 support (for both Linux and Windows OS). Intel Matrix Storage Manager with RAID 0, RAID 1, RAID 10, and RAID 5 support (for Windows OS only). 5.1.
5.1.3 RAID controller selection You can choose either the LSI Software RAID Configuration Utility or the Intel Matrix Storage Manager as the default utility to create RAID set(s). See 5. RAID configuration utility selection on page 2-20 for details. 5.1.4 Setting the RAID item in BIOS You must enable the RAID function in the BIOS Setup before creating RAID set(s) using SATA HDDs. To do this: 1. Enter the BIOS Setup during POST. 3. Set the Configure SATA as item to [RAID]. 2. 4.
5.2 LSI Software RAID Configuration Utility The LSI MegaRAID software RAID configuration utility allows you to create RAID 0, RAID 1, or RAID 10 set(s) from SATA hard disk drives connected to the SATA connectors supported by the motherboard southbridge chip. To enter the LSI MegaRAID software RAID configuration utility 1. 2. Turn on the system after installing all the SATA hard disk drives.
Menu Description Configure Allows you to create RAID 0, RAID 1 or RAID 10 set using the Easy Configuration or the New Configuration command.
2. The ARRAY SELECTION MENU displays the available drives connected to the SATA ports. Use the up/down arrow key to select the drives you want to include in the RAID set, and then press . When selected, the drive indicator changes from READY to ONLIN A[X]-[Y], where X is the array number, and Y is the drive number. LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008 BIOS Version A.08.
5. Press again, the virtual drive information appears including a Virtual Drive menu that allows you to change the virtual drive parameters. LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008 BIOS Virtual VersionDrive(s) A.08.
8. 9. When creating a RAID 1 or a RAID 10 set, select DWC from the Virtual Drive menu, and then press . When creating a RAID 0 set, proceed to step 10. Select On to enable the Disk Write Cache setting, and then press . LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008 BIOSVirtual VersionDrive(s) A.08.
11. Follow step 2 to 10 to configure additional virtual drives. 12. Press to finish RAID configuration. When prompted to save configuration, select Yes from the menu, and then press . LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008 BIOS Version A.08.
2. Follow step 2 to 7 of the previous section: Using Easy Configuration. 4. Key-in the desired virtual drive size, and then press . 3. Select Size from the Virtual Drive menu, and then press . LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008 BIOS Virtual VersionDrive(s) A.08.
5.2.2 Adding or viewing a RAID configuration You can add a new RAID configuration or view an existing configuration using the View/Add Configuration command. Adding a new RAID configuration To add a new RAID configuration: 1. From the Management Menu, select Configure > View/Add Configuration, and then press . LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008 BIOS Version A.08.
5.2.3 Initializing the virtual drives After creating the RAID set(s), you must initialize the virtual drives. You may initialize the virtual drives of a RAID set(s) using the Initialize or Objects command on the Management Menu. Using the Initialize command To initialize the virtual drive using the Initialize command 1. From the Management Menu, select Initialize, and then press . LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008 BIOS Version A.08.
3. Press to start initialization. When prompted, select Yes from the Initialize? dialog box, and then press . LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008 BIOS Version A.08.
Using the Objects command To initialize the virtual drives using the Objects command 1. From the Management Menu, select Objects > Virtual Drive, and then press . LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008 BIOS Version A.08.09161344R Objects Management Menu Adapter Configure Virtual Drive Initialize Physical Drive Objects Rebuild Check Consistency Change VD Parameters Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2.
3. Select Initialize from the pop-up menu, and then press to start initialization. LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008 BIOS Version A.08.09161344R Vitual Drive(1) Virtual Drive 0 Objects Management Menu Adapter Configure Virtual Drive Initialize Physical Drive Objects Vitual Drive(0) Rebuild Initialze Check Consistency Check Consistency View/Update Parameters Initilize VD Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 4.
5.2.4 Rebuilding failed drives You can manually rebuild failed hard disk drives using the Rebuild command in the Management Menu. To rebuild a failed hard disk drive 1. From the Management Menu, select Rebuild, and then press . LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008 BIOS Version A.08.09161344R Management Menu Configure Initialize Objects Rebuild Check Consistency Rebuild PD(s) Use Cursor Keys To Navigate Between Items And Press Enter To Select An Option 2.
3. After selecting the drive to rebuild, press . When prompted, press to rebuild the drive. LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008 BIOS Version A.08.09161344R REBUILD - PHYSICAL DRIVES SELECTION MENU Management Menu PORT # Configure 0 ONLIN A00-00 Initialize Objects 1 RBLD A00-01 Rebuild Check Consistency Rebuilding Of Drive Will Take A Few Minutes.
5.2.5 Checking the drives for data consistency You can check and verify the accuracy of data redundancy in the selected virtual drive. The utility can automatically detect and/or detect and correct any differences in data redundancy depending on the selected option in the Objects > Adapter menu. The Check Consistency command is available only for virtual drives included in a RAID 1 or RAID 10 set. Using the Check Consistency Command To check data consistency using the Check Consistency command 1.
3. When prompted, use the arrow keys to select Yes from the Consistency Check? dialog box, and then press . LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008 BIOS Version A.08.
Using the Objects command To check data consistency using the Objects command 1. 2. 3. 4. 5. From the Management Menu, select Objects, and then select Virtual Drive from the sub-menu. Use the arrow keys to select the virtual drive you want to check, and then press . Select Check Consistency from the pop-up menu, and then press . When prompted, use the arrow keys to select Yes from the dialog box to check the drive. When checking is complete, press any key to continue.
5.2.6 Deleting a RAID configuration To delete a RAID configuration 1. From the Management Menu, select Configure > Clear Configuration, and then press . LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008 BIOS Version A.08.
5.2.7 Selecting the boot drive from a RAID set You must have created a new RAID configuration before you can select the boot drive from a RAID set. See section 5.2.1 Creating a RAID set: Using New Configuration for details. To select the boot drive from a RAID set 1. From the Management Menu, select Configure > Select Boot Drive, and then press . LSI Software RAID Configuration Utility Ver A.60 Jul 30, 2008 BIOS Version A.08.
5.2.8 Enabling WriteCache You may manually enable the RAID controller’s WriteCache option after creating a RAID set to improve the data transmission performance. When you enable WriteCache, you may lose data when a power interruption occurs while transmitting or exchanging data among the drives. The WriteCache function is recommended for RAID 1 and RAID 10 sets. To enable WriteCache 1. 2. From the Management Menu, select Objects > Adapter, and then press to display the adapter properties.
5.3 Intel® Matrix Storage Manager Option ROM Utility The Intel® Matrix Storage Manager Option ROM utility allows you to create RAID 0, RAID 1, RAID 10 (RAID 0+1), and RAID 5 set(s) from Serial ATA hard disk drives that are connected to the Serial ATA connectors supported by the Southbridge. To enter the Intel® Matrix Storage Manager option ROM utility: 1. Install all the Serial ATA hard disk drives. 3. During POST, press to display the utility main menu. 2. Turn on the system.
5.3.1 Creating a RAID set To create a RAID set 1. From the utility main menu, select 1. Create RAID Volume and press . The following screen appears. Intel(R) Matrix Storage Manager option ROM v8.5.0.1030 ICH10R/DO wRAID5 Copyright(C) 2003-08 Intel Corporation. All Rights Reserved. [ CREATE VOLUME MENU ] Name: RAID Level: Disks: Strip Size: Capacity: Sync: Volume0 RAID0(Stripe) Select Disks 128KB 0.
6. Use the up/down arrow key to select the stripe size for the RAID array (for RAID 0, 10 and 5 only), and then press . The available stripe size values range from 4 KB to 128 KB. The following are typical values: RAID 0: 128KB RAID 10: 64KB RAID 5: 64KB We recommend a lower stripe size for server systems, and a higher stripe size for multimedia computer systems used mainly for audio and video editing. 7. 8.
2. 3. 4. Enter a name for the recovery set and press . When the RAID Level item is selected, press the up/down arrow key to select Recovery, and then press . When the Disks item is selected, press to select the hard disk drives you want to include in the recovery set. The SELECT DISKS screen appears. [ SELECT DISKS ] Port 0 1 2 3 Drive Model ST3160812AS ST3160812AS ST3160812AS ST3160812AS Serial # 9LS0HJA4 9LS0F4HL 3LS0JYL8 9LS0BJ5H Size 149.0GB 149.0GB 149.0GB 149.
5.3.3 Deleting a RAID set Take caution when deleting a RAID set. You will lose all data on the hard disk drives when you delete a RAID set. To delete a RAID set 1. From the utility main menu, select 2. Delete RAID Volume and press . The following screen appears. Intel(R) Matrix Storage Manager option ROM v8.5.0.1030 ICH10R/DO wRAID5 Copyright(C) 2003-08 Intel Corporation. All Rights Reserved. [ DELETE VOLUME MENU ] Name Volume0 Level RAID0(Stripe) Drives 2 Capacity 298.
5.3.4 Resetting disks to Non-RAID Take caution before you reset a RAID volume hard disk drive to non-RAID. Resetting a RAID volume hard disk drive deletes all internal RAID structure on the drive. To reset a RAID set hard disk drive 1. From the utility main menu, select 3. Reset Disks to Non-RAID and press . The following screen appears. [ RESET RAID DATA ] Resetting RAID disk will remove its RAID structures and revert it to a non-RAID disk.
5.3.5 Recovery Volume Options If you have created a recovery set, you can configure more recovery set options following the descriptions in the section. See section 5.3.2 Creating a Recovery set to create a recovery set before you continue. To configure a recovery set 1. From the utility main menu, select 4. Recovery Volume Options and press . The following screen appears. Intel(R) Matrix Storage Manager option ROM v8.5.0.1030 ICH10R/DO wRAID5 Copyright(C) 2003-08 Intel Corporation.
5.3.6 Exiting the Intel® Matrix Storage Manager To exit the utility 1. From the utility main menu, select 5. Exit, and then press . The following warning message appears. [ CONFIRM EXIT ] Are you sure you want to exit? (Y/N): 2. Press to exit or press to return to the utility main menu. 5.3.7 Rebuilding the RAID This option is only for the RAID 1 set.
3. The utility immediately starts rebuilding after the disk is selected. The status of the degraded RAID volume is changed to “Rebuild”. Intel(R) Matrix Storage Manager option ROM v8.5.0.1030 ICH10R/DO wRAID5 Copyright(C) 2003-08 Intel Corporation. All Rights Reserved. [ MAIN MENU ] 1. Create RAID Volume 2. Delete RAID Volume 3. Reset Disks to Non-RAID 4. Recovery Volume Options 5.
5.3.8 Setting the Boot array in the BIOS Setup Utility You can set the boot priority sequence in the BIOS for your RAID arrays when creating multi-RAID using the Intel® Matrix Storage Manager. To set the boot array in the BIOS: Set at least one of the arrays bootable to boot from the hard disk. 1. 2. 3. 4. 5. 5-32 Reboot the system and press to enter the BIOS setup utility during POST. Go to the Boot menu and select the option Boot Device Priority.
This chapter provides instructions for installing the necessary drivers for different system components.
Chapter summary 6 6.1 RAID driver installation................................................................ 6-1 6.3 LAN driver installation................................................................ 6-13 6.2 6.4 6.5 Intel chipset device installation................................................. 6-11 VGA driver installation............................................................... 6-16 Management application and utilities installation...................
6.1 RAID driver installation After creating the RAID sets for your server system, you are now ready to install an operating system to the independent hard disk drive or bootable array. This part provides instructions on how to install the RAID controller drivers during OS installation. 6.1.1 Creating a RAID driver disk You may have to use another system to create the RAID driver disk from the system/motherboard support DVD or from the Internet.
ICH10R LSI RAID Driver ICH10R LSI RAID Driver Windows XP / Windows Server 2003 32 Windows XP / Windows Server 2003 64 Windows Vista / Windows Server 2008 Windows Vista / Windows Server 2008 RHEL AS4 UP6 32/64 bit RHEL AS4 UP7 32/64 bit RHEL 5 UP1 32/64 bit RHEL 5 UP2 32/64 bit SLES 9 SP3 32 bit SLES 9 SP3 64 bit SLES 9 SP4 32 bit SLES 9 SP4 64 bit SLES 10 SP1 32 bit SLES 10 SP1 64 bit SLES 10 SP2 32 bit SLES 10 SP2 64 bit Back Exit bit bit 32 bit 64 bit Write DMI Write DMI RS700-E6-RS4 system RS500-E6-PS4
To create a RAID driver disk in Windows® environment 1. Start Windows®. 3. Go to the Make Disk menu, and then select the type of RAID driver disk you want to create. 2. 4. 5. Place the motherboard support DVD into the optical drive. Insert a floppy disk into the floppy disk drive. Follow succeeding screen instructions to complete the process. Write-protect the floppy disk to avoid computer virus infection. To create a RAID driver disk in Red Hat® Enterprise Linux server environment: 1. 2.
6.1.2 Installing the RAID controller driver Windows® Server OS During Windows® Server OS installation To install the RAID controller driver when installing Windows® Server OS: 1. Boot the computer using the Windows® Server installation DVD. The Windows® Server OS Setup starts. Windows Setup Press F6 if you need to install a third party SCSI or RAID driver... 2. 3. Press when the message “Press F6 if you need to install a third party SCSI or RAID driver...” appears at the bottom of the screen.
4. Insert the RAID driver disk you created earlier to the floppy disk drive, then press . Windows Setup Please insert the disk labeled Manufacturer-supplied hardware support disk into Drive A: * Press ENTER when ready. ENTER=Continue 5. 6. 7. ESC=Cancel F3=Exit Select the RAID controller driver you need from the list, then press . The Windows® Setup loads the RAID controller drivers from the RAID driver disk. When prompted, press to continue installation.
To verify the RAID controller driver installation: 1. 2. 3. Right-click the My Computer icon on the Windows® desktop, and then select Properties from the menu. Click the Hardware tab, and then click the Device Manager button. Click the “+” sign before the item SCSI and RAID controllers, and then the Intel(R) ICH8R/ICH9R/ICH10R/DO SATA RAID Controller item should appear. The screen differs based on the controller. 4. 5. 6.
Red Hat® Enterprise To install the RAID controller driver when installing Red Hat® Enterprise OS 1. 2. Boot the system from the Red Hat® Installation DVD. At the boot:, type linux dd , then press . - To install or upgrade in graphical mode, press the key. - To install or upgrade in text mode, type: linux text . - Use the function keys listed below for more information. [F1-Main] [F2-Options] [F3-General] [F4-Kernel] [F5-Rescue] boot: linux dd 3.
5. Insert the Red Hat® Enterprise RAID driver disk to the floppy disk drive, select OK, then press . Insert Driver Disk Insert your driver disk into /dev/fd0 and press “OK” to continue. OK Back The drivers for the RAID card are installed to the system. 6. When asked if you will load additional RAID controller drivers, select No, then press . More Driver Disks? Do you wish to load any more driver disks? Yes 7. 6-8 No Follow the screen instructions to continue the OS installation.
SUSE Linux OS To install the RAID controller driver when installing������������������������������ SUSE Linux Enterprise Server OS 1. 2. Boot the system from the SUSE OS installation DVD. Use the arrow keys to select Installation from the Boot Options menu. Boot from Hard Disk Installation Installation--ACPI Disabled Installation--Local APIC Disabled Installation--Safe Settings Rescue System Memory Test Boot Options | F1 Help F2 Language F3 1280 x 1024 F4 DVD F5 Driver 3.
4. Insert the RAID driver disk to the floppy disk drive. Ensure that Installation from the Boot Options menu is selected, then press . Boot from Hard Disk Installation Installation--ACPI Disabled Installation--Local APIC Disabled Installation--Safe Settings Rescue System Memory Test Boot Options | F1 Help F2 Language F3 1280 x 1024 F4 DVD F5 Driver 5. When below screen appears, select the floppy disk drive (fd0) as the driver update medium. Select OK, then press .
6.2 Intel® chipset device installation This section provides instructions on how to install the Plug and Play components for the Intel® chipset on the system. You need to manually install the Intel® chipset software on a Windows Server operating system. To install the Intel® chipset device software: 1. 2. 3. 4. Restart the computer, then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive.
6-12 5. Select Yes to accept the terms of the License Agreement and continue the process. 6. Read the Readme File Information and press Next to continue the installation. 7. After completing the installation, click Finish to complete the setup process.
6.3 LAN driver installation This section provides instructions on how to install the Intel® Gigabit LAN controller drivers on a Windows® Server OS. To install the LAN controller drivers 1. 2. Restart the computer, and then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive. The DVD automatically displays the Drivers menu if Autorun is enabled in your computer. • Windows® automatically detects the LAN controllers and displays a New Hardware Found window.
6-14 5. Click Next when the Intel(R) Network Connections–InstallShield Wizard window appears. 6. Toggle I accept the terms in the license agreement and click Next to continue. 7. Click the Intel(R) PROSet for Windows Device Manager box, and then click Next to start the installation.
8. Follow the screen instructions to complete installation. 9. When finished, press Finish to continue.
6.4 VGA driver installation This section provides instructions on how to install the Aspeed® AST2050 Video Graphics Adapter (VGA) driver. You need to manually install the Aspeed® AST2050 VGA driver on a Windows® Server operating system. To install the Aspeed® AST2050 VGA driver 1. 2. Restart the computer, then log on with Administrator privileges. Insert the motherboard/system support DVD to the optical drive.
4. Click Install to update the VGA driver. 5. When the installation completes, click Finish to restart your computer before using the program.
6.5 Management applications and utilities installation The support DVD that came with the motherboard package contains the drivers, management applications, and utilities that you can install to avail all motherboard features. The contents of the support DVD are subject to change at any time without notice. Visit the ASUS website (www.asus.com) for updates. 6.5.1 Running the support DVD Place the support DVD to the optical drive.
6.5.3 Utilities menu The Utilities menu displays the software applications and utilities that the motherboard supports. Click an item to install. 6.5.4 Make disk menu The Make disk menu contains items to create the Intel ICH10R and LSI MegaRAID driver disks. 6.5.5 Contact information Click the Contact tab to display the ASUS contact information. You can also find this information on the inside front cover of this user guide.
6-20 Chapter 6: Driver installation
This appendix includes additional information that you may refer to when configuring the motherboard.
Appendix summary A.1 A Z8NR-D12 model block diagram..................................................
A.
A-2 Appendix A: Reference information