User Manual
Table Of Contents
- Safety information
- Chapter 1: Product Introduction
- Chapter 2: Basic Installation
- Chapter 3: BIOS Setup
- 3.1 Knowing BIOS
- 3.2 BIOS setup program
- 3.3 My Favorites
- 3.4 Main menu
- 3.5 Ai Tweaker menu
- 3.6 Advanced menu
- 3.6.1 CPU Configuration
- 3.6.2 PCH Configuration
- 3.6.3 PCH Storage Configuration
- 3.6.4 System Agent Configuration
- 3.6.5 USB Configuration
- 3.6.6 Platform Misc Configuration
- 3.6.7 Onboard Devices Configuration
- 3.6.8 APM Configuration
- 3.6.9 Network Stack Configuration
- 3.6.10 HDD/SDD SMART Information
- 3.6.11 Intel(R) Ethernet Controller - 00:1E:99:00:01:1B
- 3.6.12 Intel(R) Ethernet Controller - 00:1E:99:00:01:1C
- 3.7 Monitor menu
- 3.8 Boot menu
- 3.9 Tool menu
- 3.10 Exit menu
- 3.11 Updating BIOS
- Chapter 4: Software Support
- 4.1 Installing an operating system
- 4.2 Support DVD information
- 4.3 Software information
- 4.4 AI Suite 3
- 4.4.1 Dual Intelligent Processors 5
- 4.4.2 TPU (Turbo Processing Unit)
- 4.4.3 Turbo App
- 4.4.4 EPU (Energy Processing Unit)
- 4.4.5 Fan Xpert 4
- 4.4.6 PC Cleaner
- 4.4.7 DIGI+ Power Control
- 4.4.8 Ai Charger+
- 4.4.9 USB 3.1 Boost
- 4.4.10 EZ Update
- 4.4.11 System Information
- 4.4.12 Mobo Connect
- 4.4.13 USB BIOS Flashback
- 4.4.14 Push Notice
- 4.5 Audio configurations
- Chapter 5: RAID Support
- Chapter 6: Multi GPU Support
- Appendix
3-56
Chapter 3: BIOS Setup
Chapter 3
The following items appear only when you set the Water Pump Control to [Auto], [PWM
Mode], and [DC Mode].
Water Pump Temperature
Use the <+> and <-> keys to adjust the upper limit of the water pump.
The values range from 45°C to 75°C. The water pump will operate at the
maximum duty cycle when the CPU temperature is higher than the limit.
Water Pump Max. Duty Cycle(%)
Use the <+> and <-> keys to adjust the maximum water pump duty cycle.
The values range from 60% to 100%. When the CPU temperature reaches
the upper limit, the water pump will operate at the maximum duty cycle.
Water Pump Middle Temperature
Use the <+> and <-> keys to adjust the water pump middle temperature.
The values range from 40°C to 75°C.
Water Pump Middle Duty Cycle(%)
Use the <+> or <-> keys to adjust the water pump middle duty cycle. The
values range from 60% to 100%.
Water Pump Lower Temperature
Use the <+> or <-> keys to adjust the lower limit of the water pump
temperature. The values range from 20°C to 75°C. The water pump will
operate at the minimum duty cycle when the CPU temperature is lower
than the limit.
Water Pump Min. Duty Cycle(%)
Use the <+> and <-> keys to adjust the minimum water pump duty cycle.
The values range from 60% to 100%. When the CPU temperature is lower
than the lower limit, the water pump will operate at the minimum duty cycle.
HAMP Fan Control [Auto]
This item allows you to set the HAMP Fan operating mode.
[Auto] Detects the type of HAMP Fan installed and automatically switches the
control modes.
[PWM Mode] Enables the HAMP Fan Control feature in PWM mode for 4-pin HAMP Fan.
[DC Mode] Enables the HAMP Fan Control feature in DC mode for 3-pin HAMP Fan.
[Disabled] Disables the HAMP Fan Control.
The following items appear only when you set the HAMP Fan Q-Fan Control to [Auto],
[PWM Mode], and [DC Mode].