User Manual
Table Of Contents
- Safety information
- Chapter 1: Product Introduction
- Chapter 2: Hardware Information
- Chapter 3: Motherboard Information
- Chapter 4: BIOS Setup
- 4.1 Managing and updating your BIOS
- 4.2 BIOS setup program
- 4.3 Main menu
- 4.4 Advanced menu
- 4.4.1 CPU Configuration
- 4.4.2 Power & Performance
- 4.4.3 Server ME Configuration
- 4.4.4 Trusted Computing
- 4.4.5 APM Configuration
- 4.4.6 Runtime Error Logging Settings
- 4.4.7 Onboard LAN Configuration
- 4.4.8 Serial Port Console Redirection
- 4.4.9 Intel TXT Information
- 4.4.10 PCI Subsystem Settings
- 4.4.11 USB Configuration
- 4.4.12 Network Stack Configuration
- 4.4.13 CSM Configuration
- 4.4.14 NVMe Configuration
- 4.4.15 WHEA Configuration
- 4.4.16 iSCSI Configuration
- 4.4.17 Tls Auth Configuration
- 4.5 Chipset menu
- 4.6 Security menu
- 4.7 Boot menu
- 4.8 Monitor menu
- 4.9 Tool menu
- 4.10 Event Logs menu
- 4.11 Save & Exit menu
- Chapter 5: RAID Configuration
- Chapter 6: Driver Installation
- Appendix
4-28
Chapter 4: BIOS Setup
PEG2 Slot Power Limit Scale [1.0x]
AllowsyoutoselectthescalefortheSlotPowerLimitValue.
Congurationoptions:[1.0x][0.1x][0.01x][0.001x]
PEG2 Physical Slot Number [3]
Allows you to set the physical slot number attached to this Port. The number has to be
globally unique within the chassis. Usethe<+>or<->toadjustthevalue.Thevalues
range from 0 to 8191.
PEG 0:1:3
PEG3 Slot Power Limit Value [75]
Settheupperlimitonpowersuppliedbyslot.Usethe<+>or<->toadjustthevalue.
The values range from 0 to 255.
PEG3 Slot Power Limit Scale [1.0x]
AllowsyoutoselectthescalefortheSlotPowerLimitValue.
Congurationoptions:[1.0x][0.1x][0.01x][0.001x]
PEG3 Physical Slot Number [3]
Allows you to set the physical slot number attached to this Port. The number has to be
globally unique within the chassis. Usethe<+>or<->toadjustthevalue.Thevalues
range from 0 to 8191.
VT-d [Enabled]
Allows you to enable or disable VT-d capability.
Congurationoptions:[Disabled][Enabled]
CRID Support [Disabled]
Allows you to enable or disable CRID control for Intel SIPP.
Congurationoptions:[Disabled][Enabled]
Above 4GB MMIO BIOS Assignment [Disabled]
Allows you to enable or disable above 4 GB memory mapped IO BIOS assignment. This is
enabled automatically if the aperture size is set to 2048MB.
Congurationoptions:[Disabled][Enabled]
The following item appears only when you set the VT-d to [Enabled].
X2APIC Opt Out [Disabled]
Allows you to enable or disable X2APIC Opt Out.
Congurationoptions:[Disabled][Enabled]