User Guide
VT6410 User Manual – IDE RAID Controller
Preliminary Revision 0.2, November 11, 2002 41 RAID Software
Technologies, Inc.
We
C
onnect
VIA Technologies Inc.
Confidential
NDA Required
Rebuild Broken RAID 0/0+1 array
After booting up the system, the RAID utility will detect if any member disk drives of the RAID 0 or 0+1 array has failed or is
absent. If the RAID utility detects any disk drive failures or missing disk drives, the status of the array will be marked as broken.
If the RAID software detects a RAID 1 array being broken, and there is a spare hard drive that could be used to rebuild the broken
array, the spare hard drive will automatically become the mirroring drive. Software will remind the user to synchronize this RAID
like the duplicating RAID 1.
If the RAID software detects a RAID 1 or 0+1 array being broken but there is no spare hard drive, the RAID software will indicate
a series of steps to repair such problem.
1. Pop up a dialog box to indicate that the RAID is broken. Click Yes to repair the array.