2-34
The system automatically combines the two power supply modules as a single one.
The combined output power varies with input voltages. Refer to the table below for
details.
2600W
Input Voltage Max. Output Power (Watt) per PSU
220-240Vac, 16A, 50/60Hz
240Vac, 16A, 50/60Hz
2600W
To enable the hot-swap feature (redundant mode), keep the total power consumption
of the system under the maximum output power of an individual power supply module.
Always use PSUs with the same watt and power rating. Combining PSUs with different
wattage (e.g. 1 x 1600 W + 1 x 2200 W) may yield unstable results and potential
damage to your system.
For steady power input, use only the power cables that come with the server system
package.
2.8.3 Rail kit
This server system supports the rail kit options listed below. For more information on rail kit
installation, refer to corresponding documentation on the ASUS support site or on the official
product site for this server system.
We strongly recommend that at least two able-bodied persons perform the installation
of the rail kit.
We recommend the use of an appropriate lifting tool or device, if necessary.
Friction rail kit