Manual
Table Of Contents
- About this guide
- Safety information
- Chapter 1: Product introduction
- Chapter 2: Hardware setup
- Chapter 3: Installation options
- Chapter 4: Motherboard info
- Chapter 5: BIOS setup
- 5.1 Managing and updating your BIOS
- 5.2 BIOS setup program
- 5.3 Main menu
- 5.4 Advanced menu
- 5.4.1 CPU Configuration
- 5.4.2 CPU Power Management Configuration
- 5.4.3 Chipset Configuration
- 5.4.4 PCH SATA Configuration
- 5.4.5 PCH SCU SAS Configuration
- 5.4.6 PCI Subsystem Settings
- 5.4.7 Onboard LAN Configuration
- 5.4.8 USB Configuration
- 5.4.9 Trusted Computing
- 5.4.10 ACPI Settings
- 5.4.11 WHEA Configuration
- 5.4.12 APM
- 5.4.13 Serial Port Console Redirection
- 5.4.14 ME Subsystem
- 5.4.15 Legacy Devices Configuration
- 5.4.16 Runtime Error Logging
- 5.5 Server Mgmt menu
- 5.6 Event Logs menu
- 5.7 Boot menu
- 5.8 Monitor menu
- 5.9 Security menu
- 5.10 Tool menu
- 5.11 Exit menu
- Chapter 6: RAID configuration
- Chapter 7: Driver installation
- 7.1 RAID driver installation
- 7.2 Intel® chipset device software installation
- 7.3 Intel@ Network Connections Software installation
- 7.4 VGA driver installation
- 7.5 Intel® C600 Series Chipset SCU SATA RAID Drivers
- 7.6 Intel® Rapid Storage Technology enterprise 3.0 installation
- 7.7 Intel® I350 Gigabit Adapters Driver installation
- 7.8 Management applications and utilities installation
- Appendix: Reference information

ASUS RS700-E7/RS4-C 5-31
Device power-up delay [Auto]
Maximum time the device will take before it property reports itself to the Host
Controller. ‘Auto’ uses default valus: for a Root port it is 100ms, for a Hub port the
delay is taken from Hub descriptor. Conguration options: [Auto] [Manual]
The following item appears only when you set
Device power-up delay
to
[Manual].
Mass Storage Devices:
AMI Virtual CDROM0 1.00 [Auto]
Mass storage device emulation type ‘Auto’ enumerates devices are emilated as ‘
CDROM’, drivers with no media will be emulated according to a drive type.
Conguration options: [Auto] [Floppy] [Forced FDD] [Hard Disk] [CD-ROM]
AMI Virtual Floppy0 1.00 [Auto]
Mass storage device emulation type ‘Auto’ enumerates devices are emilated as ‘
CDROM’, drivers with no media will be emulated according to a drive type.
Conguration options: [Auto] [Floppy] [Forced FDD] [Hard Disk] [CD-ROM]
AMI Virtual HDISK0 1.00 [Auto]
Mass storage device emulation type ‘Auto’ enumerates devices are emilated as ‘
CDROM’, drivers with no media will be emulated according to a drive type.
Conguration options: [Auto] [Floppy] [Forced FDD] [Hard Disk] [CD-ROM]
USB Hardware Delays and Time-outs
USB transfer time-out [20 sec]
The time-out value for control, bulk, and interrupt transfer.
Conguration options: [1 sec] [5 sec] [10 sec] [20 sec]
Device reset time-out [20 sec]
USB mass storage device start unit command time-out.
Conguration options: [10 sec] [20 sec] [30 sec] [40 sec]