Manual
Table Of Contents
- About this guide
- Safety information
- Chapter 1: Product introduction
- Chapter 2: Hardware setup
- Chapter 3: Installation options
- Chapter 4: Motherboard info
- Chapter 5: BIOS setup
- 5.1 Managing and updating your BIOS
- 5.2 BIOS setup program
- 5.3 Main menu
- 5.4 Advanced menu
- 5.4.1 CPU Configuration
- 5.4.2 CPU Power Management Configuration
- 5.4.3 Chipset Configuration
- 5.4.4 PCH SATA Configuration
- 5.4.5 PCH SCU SAS Configuration
- 5.4.6 PCI Subsystem Settings
- 5.4.7 Onboard LAN Configuration
- 5.4.8 USB Configuration
- 5.4.9 Trusted Computing
- 5.4.10 ACPI Settings
- 5.4.11 WHEA Configuration
- 5.4.12 APM
- 5.4.13 Serial Port Console Redirection
- 5.4.14 ME Subsystem
- 5.4.15 Legacy Devices Configuration
- 5.4.16 Runtime Error Logging
- 5.5 Server Mgmt menu
- 5.6 Event Logs menu
- 5.7 Boot menu
- 5.8 Monitor menu
- 5.9 Security menu
- 5.10 Tool menu
- 5.11 Exit menu
- Chapter 6: RAID configuration
- Chapter 7: Driver installation
- 7.1 RAID driver installation
- 7.2 Intel® chipset device software installation
- 7.3 Intel@ Network Connections Software installation
- 7.4 VGA driver installation
- 7.5 Intel® C600 Series Chipset SCU SATA RAID Drivers
- 7.6 Intel® Rapid Storage Technology enterprise 3.0 installation
- 7.7 Intel® I350 Gigabit Adapters Driver installation
- 7.8 Management applications and utilities installation
- Appendix: Reference information

ASUS RS700-E7/RS4-C 6-13
3. Press <F10> to start initialization. When prompted, select
Yes
from the
Initialize?
dialog box, and then press <Enter>.
Initializing a virtual drive erases all data on the drive.
4. A progress bar appears on screen. If desired, press <Esc> to abort
initialization. When initialization is completed, press <Esc>.
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
Virtual Drive(s) Congured
LD RAID Size #Stripes StripSz Status
0 1 148.580GB 2 64 KB ONLINE
Virtual Drives
Virtual Drive 0
Initialize?
Yes
No
Init Will Destroy Data On Selected VD(s)
LSI Software RAID Conguration Utility Ver C.05 Sep 17, 2010
BIOS Version A.10.09231523R
SPACE-(De)Select, F10-Initialize
Management Menu
Congure
Initialize
Objects
Rebuild
Check Consistency
Virtual Drive(s) Congured
LD RAID Size #Stripes StripSz Status
0 10 154494MB 4 64 KB ONLINE
Virtual Drives
Virtual Drive 0
Init Of VD Is In Process
VD 0 Initialization Complete. Press Esc..
¦
100% Completed
LSI Software RAID Conguration Utility Ver C.05 Sep 17, 2010
BIOS Version A.10.09231523R
SPACE-(De)Select, F10-Initialize