User Manual

50
Parameter Specification
Shock (System)
Unpackaged/Packaged
Random profile 5 Hz @ 0.001 g
^
2/Hz to 20 Hz @ 0.01
g
^
2/Hz (slope up)
20 Hz to 500Hz @ 0.01 g
^
2/Hz (flat)
Input acceleration is 2.20gRMS
NOTE:
The operating temperature of the system may be determined by
measuring the air temperature from the junction of the heatsink fins and
fan, next to the attachment screw, in a closed chassis, while the system is
in operation.
Before attempting to operate this system, the overall temperature of the
system must be above the minimum operating temperature specified.
It is recommended that the system temperature be at least room
temperature before attempting to power on the system. The operating
and non-operating environment must avoid condensing humidity.