User Manual

64
ROG MAXIMUS XI EXTREME BIOS Manual
WATER_PUMP+ 1-2 Middle Temperature
Use the <+> or <-> keys to adjust the middle limit of the water WATER_
PUMP+ temperature.
WATER_PUMP+ 1-2 Middle. Duty Cycle (%)
Use the <+> or <-> keys to adjust the maximum water WATER_PUMP+
duty cycle. When the CPU temperature reaches the upper limit, the water
WATER_PUMP+ will operate at the maximum duty cycle.
WATER_PUMP+ 1-2 Lower Temperature
Use the <+> or <-> keys to adjust the lower limit of the water WATER_
PUMP+ temperature. The water WATER_PUMP+ will operate at the
minimum duty cycle when the temperature is lower than the limit.
WATER_PUMP+ 1-2 Min. Duty Cycle(%)
Use the <+> or <-> keys to adjust the minimum water WATER_PUMP+
duty cycle. When the CPU temperature is under the limit, the water
WATER_PUMP+ will operate at the minimum duty cycle.
CPU Temperature LED Switch
This item allows you to turn the CPU Temperature LED on or off.
Conīæguration options: [On] [Off]