User’s Manual
Table Of Contents
- About this guide
- Chapter 1: Getting Started
- Chapter 2: Main Menu Overview
- Chapter 3: Deploy Management
- 3.1 Agent Management overview
- 3.2 Deploying agents
- 3.2.1 Automatically scanning and deploying to devices
- 3.2.2 Scanning an IP range
- 3.2.3 Adding and deploying to devices
- 3.2.4 Editing device information
- 3.2.5 Installing agents manually
- 3.2.6 Installing Agents in silent mode
- 3.2.7 Upgrading or repairing agents
- 3.2.8 Setting up a Windows 7 deployment environment
- 3.3 Removing agents
- 3.4 Client Agent Updater
- Chapter 4: Device Information
- Chapter 5: Management Functions
- 5.1 Metadata Management
- 5.2 Software Management
- 5.3 Task Scheduler
- 5.4 OOB Control
- 5.5 Management Control Overview
- 5.6 Management Control Information Overview
- 5.7 DASH Management Control Information
- 5.8 RTL8117 Management Control Information
- 5.9 vPro Management Control Information
- 5.10 BMC Management Control Information
- 5.10.1 Hardware Sensor
- 5.10.2 Inventory
- 5.10.3 Control
- 5.10.4 Remote Desktop
- 5.10.5 Smart BIOS
- 5.10.6 Firmware Update
- 5.10.7 Event Log
- 5.10.8 IPMI
- 5.10.9 IPMI Serial-over-LAN (SOL)
- 5.10.10 Settings
- 5.10.11 Configuration
- 5.10.12 FRU Information
- 5.10.13 Image Redirection
- 5.10.14 Platform Event Filters
- 5.10.15 BSOD Capture
- 5.10.16 Error Codes
- 5.11 Screen Broadcast
- Chapter 6: Settings Migrator
- Chapter 7: Report Generator
- Chapter 8: Account & General Settings
2-12 Chapter 2: Main Menu Overview
Remote Control
Restart computer
Restart the selected device(s).
Power off
Power off the selected device(s).
Power on
Power on the selected device(s).
A powered off client device can only be powered on if
it supports Wake on LAN.
OOB-Control
• Only available on client devices connected using a management LAN port
with motherboards which support remote management controllers.
• The
OOB-Control
menu includes functions from the 4 remote
management controllers: BMC, DASH, RTL8117, and vPro. If a selected
device does not support a selected function, you can view related
information in the mission center after executing the function.
• Power control
Power On (G0/S0)
Power on the selected device(s) through the remote
management controller.
Power Off - Soft (G2/
S5)
Power off the selected device(s) through the remote
management controller.
Power Off - Hard (G3)
Force a power off of the selected device(s) through the
remote management controller.
Power Cycle - Soft
off (G2/S5)
Set the selected device(s) to restart after shutting down the
OS through the remote management controller.
Sleep - Deep (G1/S3)
Set the selected device(s) to enter sleep mode (G1/S3)
through the remote management controller.
Master Bus Reset
Reset the hardware of the selected device(s) through the
remote management controller.
Hibernate (G1/S4)
Set the selected device(s) to enter hibernate mode (G1/S4)
through the remote management controller.
Restart Computer to
BIOS
Set the selected device(s) to enter BIOS after a restart
through the remote management controller.
Power On to BIOS
Set the selected device(s) to enter BIOS after powering on
through the remote management controller.
Restart Computer to
IDE-R Floppy
Set the selected device(s) to enter IDE-R floppy drive after a
restart through the remote management controller.
Power On to IDE-R
Floppy
Set the selected device(s) to enter IDE-R floppy drive after
powering on through the remote management controller.