User’s Manual

Table Of Contents
5-147ASUS Control Center Express
Fan Mode
This item allows you to view the current fan mode and switch between different
fan modes.
Generic Mode
Set the fan of the client device to generic mode.
Full Speed Mode
Set the fan of the client device to full speed mode.
Fan Customized
This item allows you to specify a custom fan curve.
Fan Temperature Source
This item allows you to select a temperature sensor to control fan speed.
If temperature information is unavailable, the CPU temperature will be
used. If the CPU temperature is also unavailable, the fan speed will default
to 60%.
To use CHA_FAN sensor and control functions, please ensure that the
fans are connected to the corresponding fan headers and that the 6-pin
PSU connector is connected to a power supply.
PSU Redundancy
This item allows you to configure PSU redundancy settings, allowing you to focus
system power consumption on one PSU device for improved power efficiency.
PSU Redundancy
Enable or disable PSU Redundancy
To use PSU Redundancy, the PSU PM_BUS header and SMART_PSU switch
jumper must be activated.
Service Web Configuration
This item allows you to configure the Web service.
Active
Enable or disable the Web service.
Interface Name
Select the interface used for the Web service.
Secure Port
Enter the secure port used for the Web service.
(default: 443)
Timeout
Configure the session timeout value in multiples of 60
seconds between 300 to 1800 seconds
Maximum Sessions
Shows the maximum number of allowed sessions.