User’s Manual
Table Of Contents
- About this guide
- Chapter 1: Getting Started
- Chapter 2: Main Menu Overview
- Chapter 3: Deploy Management
- 3.1 Agent Management overview
- 3.2 Deploying agents
- 3.2.1 Automatically scanning and deploying to devices
- 3.2.2 Scanning an IP range
- 3.2.3 Adding and deploying to devices
- 3.2.4 Editing device information
- 3.2.5 Installing Agents manually
- 3.2.6 Installing Agents in silent mode
- 3.2.7 Upgrading older versions of agents or repairing agents
- 3.2.8 Setting up a Windows 7 deployment environment
- 3.3 Removing agents
- 3.4 Client Agent Updater
- Chapter 4: Device Information
- Chapter 5: Management Functions
- 5.1 Metadata Management
- 5.2 Software Management
- 5.3 Task Scheduler
- 5.4 OOB Control
- 5.5 Management Control Overview
- 5.6 Management Control Information Overview
- 5.7 DASH Management Control Information
- 5.8 RTL8117 Management Control Information
- 5.9 vPro Management Control Information
- 5.10 BMC Management Control Information
- 5.10.1 Hardware Sensor
- 5.10.2 Inventory
- 5.10.3 Control
- 5.10.4 Remote Desktop
- 5.10.5 Smart BIOS
- 5.10.6 Firmware Update
- 5.10.7 Event Log
- 5.10.8 IPMI
- 5.10.9 IPMI Serial-over-LAN (SOL)
- 5.10.10 Settings
- 5.10.11 Configuration
- 5.10.12 FRU Information
- 5.10.13 Image Redirection
- 5.10.14 Platform Event Filters
- 5.10.14 BSOD Capture
- 5.11 Screen Broadcast
- Chapter 6: Settings Migrator
- Chapter 7: Report Generator
- Chapter 8: Account & General Settings
5-135ASUS Control Center Express
5.10.7 Event Log
This item allows you to view the event log of the last time the client device was
powered on, giving you more information to analyze the cause of the problem or
issue.
Please use the Notification Rule Management menu to manage which client
devices, utilization status messages, hardware sensor events, or management
controller alarms are shown in the Event Log. To set up notification rules,
please click on located at the top right menu bar of the Dashboard, then
select
Options
>
Rule Management
. For more information, please refer to
8.1.2
Rule Management
.
To execute commands on multiple client devices, please return to the main
control panel and select the devices you wish to send commands to, then click
Select Function
>
OOB - Control
>
IPMI
>
IPMI Tool Lanplus Command
Redirect
5.10.8 IPMI
IPMI Tool Lanplus Command Redirect allows remote execution of commands to
configure settings or view information on the client device.
In order to write FRU data, please unlock the FRU by executing the following
command:
raw 0x30 0x17 0x01
Once the FRU is unlocked, execute the following command to write FRU data:
fru write <fru id> <file>