User’s Manual
Table Of Contents
- About this guide
- Chapter 1: Getting Started
- Chapter 2: Main Menu Overview
- Chapter 3: Deploy Management
- 3.1 Agent Management overview
- 3.2 Deploying agents
- 3.2.1 Automatically scanning and deploying to devices
- 3.2.2 Scanning an IP range
- 3.2.3 Adding and deploying to devices
- 3.2.4 Editing device information
- 3.2.5 Installing Agents manually
- 3.2.6 Installing Agents in silent mode
- 3.2.7 Upgrading older versions of agents or repairing agents
- 3.2.8 Setting up a Windows 7 deployment environment
- 3.3 Removing agents
- 3.4 Client Agent Updater
- Chapter 4: Device Information
- Chapter 5: Management Functions
- 5.1 Metadata Management
- 5.2 Software Management
- 5.3 Task Scheduler
- 5.4 OOB Control
- 5.5 Management Control Overview
- 5.6 Management Control Information Overview
- 5.7 DASH Management Control Information
- 5.8 RTL8117 Management Control Information
- 5.9 vPro Management Control Information
- 5.10 BMC Management Control Information
- 5.10.1 Hardware Sensor
- 5.10.2 Inventory
- 5.10.3 Control
- 5.10.4 Remote Desktop
- 5.10.5 Smart BIOS
- 5.10.6 Firmware Update
- 5.10.7 Event Log
- 5.10.8 IPMI
- 5.10.9 IPMI Serial-over-LAN (SOL)
- 5.10.10 Settings
- 5.10.11 Configuration
- 5.10.12 FRU Information
- 5.10.13 Image Redirection
- 5.10.14 Platform Event Filters
- 5.10.14 BSOD Capture
- 5.11 Screen Broadcast
- Chapter 6: Settings Migrator
- Chapter 7: Report Generator
- Chapter 8: Account & General Settings
5-52 Chapter 5: Management Functions
USB Redirection
Use the USB redirection function of the selected RTL8117,
DASH, or vPro device(s); or enable or disable the USB
redirection function for selected RTL8117 and vPro device(s).
Firmware Update
Update the BMC or RTL8117 firmware for selected device(s).
Trust Zone
Set the main server IP addresses which are allowed to perform
RTL8117 function operations on client devices.
Certificate Management
Manage the certificates for selected vPro device(s).
System Trap Alert
Set the system Trap Alert level, or enable or disable Trap Alert
for DASH and vPro device(s).
IPMI
Configure command redirection; or write information from the
FRU(s) on selected BMC device(s).
Settings
Configure settings for selected BMC device(s).
Function descriptions
• OOB - Control functions are a collection of BMC, DASH, RTL8117, and
vPro remote management controller functions. If a selected device does
not support a selected OOB - Control function, you can view the details
and results of the action in the Mission Center.
• Selected OOB - Control functions may not be able to be executed together
due to differences between the remote management controllers, for
example, USB Redirection function for vPro cannot be executed at the
same time as the USB Redirection function for DASH or RTL8117.
• The USB redirection function for DASH and vPro does not support NTFS
format USB devices.
• When using the USB redirection function for vPro, the client device will
be displayed as Floppy Disk A, CD Drive (drive code) when successfully
mounted.
• When using the KVM remote desktop function of a vPro device, the border
of the client device screen will flash red and yellow to indicate that the
client device is currently running the KVM remote desktop function.
• You can add or edit remote management controller notifications in
Notification Rule. The Event Log on the dashboard will display the system
Trap Alert notifications you have set.