5-51ASUS Control Center Express
• OOB - Control functions are a collection of DASH, RTL8117, and vPro
remote management controller functions. If a selected device does not
support a selected OOB - Control function, you can view the details and
results of the action in the Mission Center.
• Selected OOB - Control functions may not be able to be executed together
due to differences between the remote management controllers, for
example, USB Redirection function for vPro cannot be executed at the
same time as the USB Redirection function for DASH or RTL8117.
• The USB redirection function for DASH and vPro does not support NTFS
format USB devices.
• When using the USB redirection function for vPro, the client device will
be displayed as Floppy Disk A, CD Drive (drive code) when successfully
mounted.
• When using the KVM remote desktop function of a vPro device, the border
of the client device screen will flash red and yellow to indicate that the
client device is currently running the KVM remote desktop function.
• You can add or edit remote management controller notifications in
Notification Rule. The Event Log on the dashboard will display the system
Trap Alert notifications you have set.
• When selecting multiple client devices to set the account and password,
ensure to select client devices with the same remote management
controller.
• The KVM password must contain 8 characters, and must contain
uppercase characters (A-Z), lowercase characters, numbers (0-9), and
special characters.
• Ensure the client device’s RTL8117 is enabled if it uses RTL8117 for
remote management control, and this is a new machine which is used for
the first time or has been reset to factory settings. In the device’s BIOS,
navigate to
Advanced
> RTL8117 setting, then enable RTL8117.
• If an agent has been deployed to the client device, you can also enable the
client device’s RTL8117 management controller through the BIOS setting
function of ASUS Control Center Express.
• You cannot update the RTL8117 remote management controller firmware
if KVM is enabled. If you wish to update the RTL8117 remote management
controller firmware please disable KVM first.