Chapter 3: Web-based User Interface
Temperature Source
This page allows you to select a desired temperature source to control your fan. If no
temperature is obtained, the CPU temperature will be used. If CPU temperature is not
obtained, fan control will be set to 60%. These settings will also be applied to every fan in
control mode.
To use the CHA FAN sensor and control function, ensure the fans are connected to the
Fan
headers 1-8
, and the
6-pin PSU connector
is connected to a power supply.
3.7.17 PSU Redundancy
This page allows you to configure PSU redundancy settings, allowing you to focus system
power consumption on one PSU device for improved power efficiency.
PSU will start balancing power when system is in heavy loading.
Enable
Enable PSU redundancy.
Disable
Disable PSU redundancy.