User Manual

74
Pro WS sTR5 Series BIOS Manual
ACPI SLIT remote inter-SLink distance
Specify the distance between two SLink domains, each on a different socket.
Configuration options: [10] - [255]
Link
GMI encryption control
Allows you to control the GMI link encryption.
Configuration options: [Disabled] [Enabled] [Auto]
DF Watchdog Timer Interval
Allows you to set the Data Fabric watchdog timer interval.
Configuration options: [Auto] [41ms] [166ms] [334ms] [669ms] [1.34 seconds] [2.68
seconds] [5.36 seconds]
Disable DF to external downstream IP Sync Flood Propagation
Disables Error propagation to UMC or any downstream slaves eg. FCH. Use this to
avoid reset in failure scenario.
Configuration options: [Sync flood disabled] [Sync flood enabled] [Auto]
Sync Flood Propagation to DF Components
Configuration options: [Sync flood disabled] [Sync flood enabled] [Auto]
Freeze DF module queues on error
Configuration options: [Disabled] [Enabled] [Auto]
System probe filter
Allows you to control whether or not the probe filter is enabled. Has no effect on parts
where the probe filter is fuse disabled.
Configuration options: [Disabled] [Enabled] [Auto]
UMC Common Options
DDR Addressing Options
Chipselect Interleaving
Interleave memory blocks across the DRAM chip selects for node 0.
Configuration options: [Disabled] [Auto]
Address Hash Bank
Allows you to enable or disable bank address hashing.
Configuration options: [Disabled] [Enabled] [Auto]
Address Hash CS
Enable or disable CS address hashing.
Configuration options: [Auto] [Enabled] [Disabled]
Address Hash Rm
Enable or disable RM address hashing.
Configuration options: [Auto] [Enabled] [Disabled]
Address Hash Subchannel
Enable or disable Sub-channel address hashing.
Configuration options: [Auto] [Enabled] [Disabled]
BankSwapMode