The following item appears only when Trc Ctrl is set to [Manual].
Trc
Specifies Active to Active/Refresh Delay Time. Valid values: 0x20 ~
0xFF. The value is in hex.
Twr Ctrl
[Auto] Follow default setting.
[Manual] Manually specify.
The following item appears only when Twr Ctrl is set to [Manual].
Twr
Specifies the Minimum Write Recovery Time. Valid values: 0x30 ~
0x60. The value is in hex.
Trfc1 Ctrl
[Auto] Follow default setting.
[Manual] Manually specify.
The following item appears only when Trfc1 Ctrl is set to [Manual].
Trfc1
Specifies the Refresh Recovery Delay Time (tRFC1). Valid values:
0x32 ~ 0xFFF. The value is in hex.
Trfc2 Ctrl
[Auto] Follow default setting.
[Manual] Manually specify.
The following item appears only when Trfc2 Ctrl is set to [Manual].
Trfc2
Specifies the Refresh Recovery Delay Time (tRFC2). Valid values:
0x32 ~ 0xFFF. The value is in hex.
TrfcSb Ctrl
[Auto] Follow default setting.
[Manual] Manually specify.
The following item appears only when TrfcSb Ctrl is set to [Manual].
TrfcSb
Specifies the Refresh Recovery Delay Time (tRFCSB). Valid values:
0x32 ~ 0x7FF. The value is in hex.
Trtp Ctrl
[Auto] Follow default setting.
[Manual] Manually specify.
The following item appears only when Trtp Ctrl is set to [Manual].
Trtp
Specifies the Read CAS# to Precharge command delay time. Valid
values: 0x5 ~ 0x1F. The value is in hex.