User’s Manual

Chassis Fan 1/2 Profile [Standard]
This item allows you to set the appropriate performance level of the chassis fan.
[Standard] Sets to [Standard] to make the chassis fan automatically adjust
depending on the chassis temperature.
[Silent] Sets to [Silent] to minimize the fan speed for quiet chassis fan
operation.
[Turbo] Sets to [Turbo] to achieve maximum chassis fan speed.
[Manual] Sets to [Manual] to assign detailed fan speed control parameters.
The following four items appear only when you set Chassis Fan 1/2 Profile to [Manual].
Chassis Fan 1/2 Upper Temperature [70]
Use the <+> or <-> keys to adjust the upper limit of the chassis fan. The values range
from 45°C to 75°C.
Chassis Fan 1/2 Max. Duty Cycle(%) [100]
Use the <+> or <-> keys to adjust the maximum chassis fan duty cycle. The values
range from 60% to 100%. When the chassis temperature reaches the upper limit, the
chassis fan will operate at the maximum duty cycle.
Chassis Fan 1/2 Middle Temperature [45]
Use the <+> or <-> keys to set the value for Chassis Fan Middle Temperature.
Chassis Fan 1/2 Middle Duty Cycle(%) [60]
Use the <+> or <-> keys to adjust the chassis fan middle duty cycle. The values range
from 60% to 100%.
Chassis Fan 1/2 Lower Temperature [40]
Use the <+> or <-> keys to adjust the chassis fans’ lower temperature. The values
range from 0°C to 75°C.
Chassis Fan 1/2 Min. Duty Cycle(%) [60]
Use the <+> or <-> keys to adjust the minimum chassis fan duty cycle. The values
range from 60% to 100%. When the CPU temperature is under the lower limit, the
chassis fan operates at the minimum duty cycle.
2.7.5 AIO PUMP Control [Disabled]
[Auto] Detects the type of AIO PUMP fan installed and automatically switch the
control modes.
[PWM mode] Enables the AIO PUMP Q-Fan control in PWM mode for 4-pin AIO PUMP
fan.
[DC mode] Enables the AIO PUMP Q-Fan control in DC mode for 3-pin AIO PUMP
fan.
[Disabled] Disables the AIO PUMP Q-Fan control feature.
The following items appear only when you set the AIO PUMP Fan Control to [PWM Mode]
or [DC Mode].
2-40 Chapter 2: Getting started