User Manual
Rev 1.50
Mellanox Technologies
21
-mac <MAC>
1
- MAC base address value. Each of the two ConnectX EN ports is assigned
a MAC address as follows:
MAC is assigned to Port 1
MAC+1 is assigned to Port 2
Affected commands: burn sg
-macs <MACs...>
1
- 2 MAC addresses must be specified here—one for each ConnectX EN
port. The first MAC address is assigned to Port 1 and the second MAC
address to Port 2.
Affected commands: burn sg
-uid <UID> - BridgeX only. Derive and set the device UIDs (GUIDs, MACs, WWNs).
UIDs are derived from the given base UID as per Mellanox’s methodol
-
ogy.
Affected commands: burn, sg
-uids <UIDs...> - BridgeX only. 29 space-separated UIDs must be specified here, in the fol-
lowing order:
G0-MAC-PI0 G0-MAC-PI1 G0-MAC-PI2
G0-MAC-PE0 G0-MAC-PE1 G0-MAC-PE2 G0-MAC-PE3
G0-FC-WWPN-P0 G0-FC-WWPN-P1 G0-FC-WWPN-P2 G0-FC-
WWPN-P3
G0-IB-NODE-GUID G0-IB-PORT-GUID G0-FC-WWNN
G1-MAC-PI0 G1-MAC-PI1 G1-MAC-PI2
G1-MAC-PE0 G1-MAC-PE1 G1-MAC-PE2 G1-MAC-PE3
G1-FC-WWPN-P0 G1-FC-WWPN-P1 G1-FC-WWPN-P2 G1-FC-
WWPN-P3
G1-IB-NODE-GUID G1-IB-PORT-GUID G1-FC-WWNN
IB-SYSTEM-GUID
Affected commands: burn, sg
-blank_guids - Burn the image with blank GUIDs and MACs (where applicable). These
values can be set later using the “sg” command (see details below).
NOTE: An image that is burnt with blank GUIDs/MACs will fail to boot
the machine as long as the GUIDs/MACs are not set.
Affected commands: burn
-clear_semaphore - Force the clearing of the Flash semaphore on the device. This flag should
come BEFORE the -d[evice] flag in the command line. No command is
allowed when this flag is used.
NOTE: Using this flag may result in an unstable behavior and flash image
corruption if the device or another flash application is currently using the
flash. Handle with care.
-byte_mode - Shift the address when accessing Flash internal registers. May be required
for burn/write commands when accessing certain Flash types on Infini
-
Host®IIIEx HCAs.
-no_flash_verify - Do not verify each write on the Flash device.
1. The -mac and -macs options are applicable only to Mellanox Technologies Ethenet adapter and switch devices.