User Manual
Rev 2.0-3.0.0
Mellanox Technologies
37
2. Your InfiniBand device is the one with the postfix “_pci_cr0”. In the example listed
above, this will be
/dev/mst/mt25418_pci_cr0.
Step 3. Burn firmware.
1. Burning a firmware binary image using mstflint (that is already installed on your
machine). Please refer to
MSTFLINT_README.txt under docs/.
2. Burning a firmware image from a .mlx file using the mlxburn utility (that is already
installed on your machine).
The following command burns firmware onto the ConnectX device with the device name
obtained in the example of Step 2.
Step 4. Reboot your machine after the firmware burning is completed.
host1# mst status
MST modules:
------------
MST PCI module loaded
MST PCI configuration module loaded
MST Calibre (I2C) module is not loaded
MST devices:
------------
/dev/mst/mt25418_pciconf0 - PCI configuration cycles access.
bus:dev.fn=02:00.0 addr.reg=88
data.reg=92
Chip revision is: A0
/dev/mst/mt25418_pci_cr0 - PCI direct access.
bus:dev.fn=02:00.0 bar=0xdef00000
size=0x100000
Chip revision is: A0
/dev/mst/mt25418_pci_msix0 - PCI direct access.
bus:dev.fn=02:00.0 bar=0xdeefe000
size=0x2000
/dev/mst/mt25418_pci_uar0 - PCI direct access.
bus:dev.fn=02:00.0 bar=0xdc800000
size=0x800000
host1$ mlxburn -dev /dev/mst/mt25418_pci_cr0 -fw /mnt/firmware/fw-25408/fw-25408-
rel.mlx