User Manual
Table Of Contents
- Mellanox WinOF VPI User Manual
- Table of Contents
- List of Tables
- Document Revision History
- About this Manual
- 1 Introduction
- 2 Firmware Upgrade
- 3 Driver Features
- 3.1 Hyper-V with VMQ
- 3.2 Header Data Split
- 3.3 Receive Side Scaling (RSS)
- 3.4 Port Configuration
- 3.5 Load Balancing, Fail-Over (LBFO) and VLAN
- 3.6 Ports TX Arbitration
- 3.7 RDMA over Converged Ethernet (RoCE)
- 3.8 Network Virtualization using Generic Routing Encapsulation
- 3.9 Differentiated Services Code Point (DSCP)
- 4 Deploying Windows Server 2012 and Above with SMB Direct
- 5 Driver Configuration
- 6 Performance Tuning
- 7 OpenSM - Subnet Manager
- 8 InfiniBand Fabric
- 8.1 Network Direct Interface
- 8.2 part_man - Virtual IPoIB Port Creation Utility
- 8.3 InfiniBand Fabric Diagnostic Utilities
- 8.3.1 Utilities Usage
- 8.3.2 ibdiagnet
- 8.3.3 ibportstate
- 8.3.4 ibroute
- 8.3.5 ibdump
- 8.3.6 smpquery
- 8.3.7 perfquery
- 8.3.8 ibping
- 8.3.9 ibnetdiscover
- 8.3.10 ibtracert
- 8.3.11 sminfo
- 8.3.12 ibclearerrors
- 8.3.13 ibstat
- 8.3.14 vstat
- 8.3.15 osmtest
- 8.3.16 ibaddr
- 8.3.17 ibcacheedit
- 8.3.18 iblinkinfo
- 8.3.19 ibqueryerrors
- 8.3.20 ibsysstat
- 8.3.21 saquery
- 8.3.22 smpdump
- 8.4 InfiniBand Fabric Performance Utilities
- 8.4.1 ib_read_bw
- 8.4.2 ib_read_lat
- 8.4.3 ib_send_bw
- 8.4.4 ib_send_lat
- 8.4.5 ib_write_bw
- 8.4.6 ib_write_lat
- 8.4.7 ibv_read_bw
- 8.4.8 ibv_read_lat
- 8.4.9 ibv_send_bw
- 8.4.10 ibv_send_lat
- 8.4.11 ibv_write_bw
- 8.4.12 ibv_write_lat
- 8.4.13 nd_write_bw
- 8.4.14 nd_write_lat
- 8.4.15 nd_read_bw
- 8.4.16 nd_read_lat
- 8.4.17 nd_send_bw
- 8.4.18 nd_send_lat
- 8.4.19 NTttcp
- 9 Software Development Kit
- 10 Troubleshooting
- 11 Documentation
- Appendix A: Windows MPI (MS-MPI)
- Appendix B: NVGRE Configuration Scrips Examples
Rev 4.60
Mellanox Technologies
89
-m, --max_lid This option specifies the maximal LID number to be searched for
during inventory file build (default to 100)
-g, --guid This option specifies the local port GUID value with which OpenSM
should bind. OpenSM may be bound to 1 port at a time. If GUID
given is 0, OpenSM displays a list of possible port GUIDs and waits
for user input. Without -g, OpenSM tries to use the default port
-p, --port This option displays a menu of possible local port GUID values with
which osmtest could bind
-i, --inventory This option specifies the name of the inventory file Normally, osmtest
expects to find an inventory file, which osmtest uses to validate real-
time information received from the SA during testing If -i is not
specified, osmtest defaults to the file osmtest.dat See -c option for
related information
-s, --stress This option runs the specified stress test instead of the normal test
suite Stress test options are as follows:
OPT Description
--- -----------------
-s1 - Single-MAD (RMPP) response SA queries
-s2 - Multi-MAD (RMPP) response SA queries
-s3 - Multi-MAD (RMPP) Path Record SA queries
-s4 - Single-MAD (non RMPP) get Path Record SA queries
Without -s, stress testing is not performed
-M, --Multicast_Mode This option specify length of Multicast test:
OPT Description
--- -----------------
-M1 - Short Multicast Flow (default) - single mode
-M2 - Short Multicast Flow - multiple mode
-M3 - Long Multicast Flow - single mode
-M4 - Long Multicast Flow - multiple mode
• Single mode - Osmtest is tested alone, with no other apps that interact
with OpenSM MC
• Multiple mode - Could be run with other apps using MC with OpenSM.
Without -M, default flow testing is performed
-t This option specifies the time in milliseconds used for transaction
timeouts. Specifying -t 0 disables timeouts. Without -t, OpenSM
defaults to a timeout value of 200 milliseconds.
-l, --log_file This option defines the log to be the given file. By default the log
goes to stdout.
-v This option increases the log verbosity level. The -v option may be
specified multiple times to further increase the verbosity level. See
the -vf option for more information about. log verbosity.
-V This option sets the maximum verbosity level and forces log flushing.
The -V is equivalent to '-vf0xFF -d 2'. See the -vf option for more
information about. log verbosity.
Table 24 - osmtest Flags and Options
Flag Description