User Manual
Table Of Contents
- Mellanox WinOF VPI User Manual
- Table of Contents
- List of Tables
- Document Revision History
- About this Manual
- 1 Introduction
- 2 Firmware Upgrade
- 3 Driver Features
- 3.1 Hyper-V with VMQ
- 3.2 Header Data Split
- 3.3 Receive Side Scaling (RSS)
- 3.4 Port Configuration
- 3.5 Load Balancing, Fail-Over (LBFO) and VLAN
- 3.6 Ports TX Arbitration
- 3.7 RDMA over Converged Ethernet (RoCE)
- 3.8 Network Virtualization using Generic Routing Encapsulation
- 3.9 Differentiated Services Code Point (DSCP)
- 4 Deploying Windows Server 2012 and Above with SMB Direct
- 5 Driver Configuration
- 6 Performance Tuning
- 7 OpenSM - Subnet Manager
- 8 InfiniBand Fabric
- 8.1 Network Direct Interface
- 8.2 part_man - Virtual IPoIB Port Creation Utility
- 8.3 InfiniBand Fabric Diagnostic Utilities
- 8.3.1 Utilities Usage
- 8.3.2 ibdiagnet
- 8.3.3 ibportstate
- 8.3.4 ibroute
- 8.3.5 ibdump
- 8.3.6 smpquery
- 8.3.7 perfquery
- 8.3.8 ibping
- 8.3.9 ibnetdiscover
- 8.3.10 ibtracert
- 8.3.11 sminfo
- 8.3.12 ibclearerrors
- 8.3.13 ibstat
- 8.3.14 vstat
- 8.3.15 osmtest
- 8.3.16 ibaddr
- 8.3.17 ibcacheedit
- 8.3.18 iblinkinfo
- 8.3.19 ibqueryerrors
- 8.3.20 ibsysstat
- 8.3.21 saquery
- 8.3.22 smpdump
- 8.4 InfiniBand Fabric Performance Utilities
- 8.4.1 ib_read_bw
- 8.4.2 ib_read_lat
- 8.4.3 ib_send_bw
- 8.4.4 ib_send_lat
- 8.4.5 ib_write_bw
- 8.4.6 ib_write_lat
- 8.4.7 ibv_read_bw
- 8.4.8 ibv_read_lat
- 8.4.9 ibv_send_bw
- 8.4.10 ibv_send_lat
- 8.4.11 ibv_write_bw
- 8.4.12 ibv_write_lat
- 8.4.13 nd_write_bw
- 8.4.14 nd_write_lat
- 8.4.15 nd_read_bw
- 8.4.16 nd_read_lat
- 8.4.17 nd_send_bw
- 8.4.18 nd_send_lat
- 8.4.19 NTttcp
- 9 Software Development Kit
- 10 Troubleshooting
- 11 Documentation
- Appendix A: Windows MPI (MS-MPI)
- Appendix B: NVGRE Configuration Scrips Examples
Rev 4.60
Mellanox Technologies
18
Step 4. Select the Driver key, and obtain the nn number.
3.4 Port Configuration
After WinOF OFED VPI installation, it is possible to modify the network protocol that runs on
each port of VPI adapter cards. Each port can be set to run as InfiniBand, Ethernet or Auto Sens-
ing.
3.4.1 Auto Sensing
Auto Sensing enables the NIC to automatically sense the link type (InfiniBand or Ethernet) based
on the cable connected to the port and load the appropriate driver stack (InfiniBand or Ethernet).
Auto Sensing is performed only when rebooting the machine or after disabling/enabling the
mlx4_bus interface from the Device Manager. Hence, if you replace cables during the runtime,
the NIC will not perform Auto Sensing.
For further information on how to configure it, please refer to Section 3.4.2, “Port Protocol Con-
figuration”, on page 19.