Step 2. Install and Run WinMFT.
To install the WinMFT package, double click the MSI package or run it from the command
prompt.
Example:
To check the device status:
Step 1. Start/Stop mst.
Step 2. Check the device’s status.
If no installation problems occur, the status command should produce the following output:
2.3 Upgrading Firmware
Firmware can be upgraded either manually or automatically as described in the sections below.
2.3.1 Upgrading Firmware Manually
To upgrade firmware manually:
Step 1. Burn the firmware image.
Example:
Step 2.
Reboot the server.
For additional details, please check the MFT user manual under:
http://www.mellanox.com > Products > Firmware Tools
Installing the WinMFT package from the command line requires administrator privi-
leges.
PS $ msiexec.exe /i WinMFT_x64_3_0_0_17.msi
PS $ mst start
OR
PS $ mst stop
PS $ mst status
PS $ mt4099_pciconf0
PS $ mt4099_pci_cr0
PS $ flint -d mt<device id>_pci_cr0 -i <image_name.bin> burn
PS $ flint -d mt4099_pci_cr0 -i fw-ConnectX3-rel-2_11_0500-MCX354A-FCA_A1.bin burn