User Manual

In case your machine has the latest firmware, no firmware update will occur and the
installation script will print at the end of installation a message similar to the following:
Device #1:
----------
Device Type: ConnectX3Pro
Part Number: MCX354A-FCC_Ax
Description: ConnectX-3 Pro VPI adapter card; dual-port
QSFP; FDR IB (56Gb/s) and 40GigE;PCIe3.0 x8 8GT/s;RoHS R6
PSID: MT_1090111019
PCI Device Name: 0000:05:00.0
Versions: Current Available
FW 2.31.5000 2.31.5000
PXE 3.4.0224 3.4.0224
Status: Up to date
In case your machine has an unsupported network adapter device, no firmware update
will occur and the error message below will be printed. Please contact your hardware
vendor for help on firmware updates.
Error message:
Device #1:
----------
Device: 0000:05:00.0
Part Number:
Description:
PSID: MT_0DB0110010
Versions: Current Available
FW 2.9.1000 N/A
Status: No matching image found
Rev 2.2-1.0.1
Mellanox Technologies
43
Step 4. Reboot the machine if the installation script performed firmware updates to your network
adapter hardware. Otherwise, restart the driver by running:
"/etc/init.d/openibd
restart"
Note: The script adds the following lines to /etc/security/limits.conf for the user-
space components such as MPI:
* soft memlock unlimited
* hard memlock unlimited
These settings set the amount of memory that can be pinned by a user space application to
unlimited. If desired, tune the value unlimited to a specific amount of RAM.
Note: For your machine to be part of the InfiniBand/VPI fabric, a Subnet Manager must be
running on one of the fabric nodes. At this point, Mellanox OFED for Linux has
already installed the OpenSM Subnet Manager on your machine. For details on start-
ing OpenSM, see Chapter 8, “OpenSM – Subnet Manager”.
Step 5. (InfiniBand only) Run the hca_self_test.ofed utility to verify whether or not the
InfiniBand link is up. The utility also checks for and displays additional information such as
HCA firmware version
Kernel architecture