User Manual

InfiniBand Fabric UtilitiesRev 2.2-1.0.1
Mellanox Technologies
262
Options
--cckey, -c <key> CC key
--config, -z <config> use config file, default: /etc/infiniband-diags/ibdiag.conf
--Ca, -C <ca> Ca name to use
--Port, -P <port> Ca port number to use
--Lid, -L use LID address argument
--Guid, -G use GUID address argument
--timeout, -t <ms> timeout in ms
--sm_port, -s <lid> SM port lid
--m_key, -y <key> M_Key to use in request
--errors, -e show send and receive errors
--verbose, -v increase verbosity level
--debug, -d raise debug level
--help, -h help message
--version, -V show version
Examples
ibccquery CongestionInfo 3 # Congestion Info by lid
ibccquery SwitchPortCongestionSetting 3 # Query all Switch Port Congestion Settings
ibccquery SwitchPortCongestionSetting 3 1 # Query Switch Port Congestion Setting for port 1
9.4.26 smparquery
The tool sends smp query for adaptive routing and private LFT features.
Synopsis
smparquery <op> <dest dr_path|lid> [op params]
Operations
CongestionLog (CL) <lid|guid>
SwitchCongestionSetting (SS) <lid|guid>
SwitchPortCongestionSetting (SP) <lid|guid> [<portnum>]
CACongestionSetting (CS) <lid|guid>
CongestionControlTable (CT) <lid|guid>
Timestamp (TI) <lid|guid>
Operation Parameters
ARInfo (ARI) <addr>
Operation Parameters