9.4.9.3 Multiple CA/Multiple Port Support
When no IB device or port is specified, the port to use is selected by the following criteria:
1. The first port that is ACTIVE.
2. If not found, the first port that is UP (physical link up).
If a port and/or CA name is specified, the user request is attempted to be fulfilled, and will fail if
it is not possible.
Examples
Direct Routed Examples:
smpdump -D 0,1,2,3,5 16 # NODE DESC
smpdump -D 0,1,2 0x15 2 # PORT INFO, port 2
LID Routed Examples:
smpdump 3 0x15 2 # PORT INFO, lid 3 port 2
smpdump 0xa0 0x11 # NODE INFO, lid 0xa0
-d Raises the IB debugging level.
Can be used several times (-ddd or -d -d -d).
-e Shows send and receive errors (timeouts and others)
-h Shows the usage message
-v Increases the application verbosity level.
Can be used several times (-vv or -v -v -v)
-V Shows the version info.
Addressing Flags Description
-D Uses directed path address arguments. The path is a comma separated list of out
ports.
Examples:
"0" # self port
"0,1,2,1,4" # out via port 1, then 2, ...
-G Uses GUID address argument. In most cases, it is the Port GUID.
Example:
"0x08f1040023"
-s <smlid> Uses ’smlid’ as the target lid for SM/SA queries.
Flags Description
-C <ca_name> Uses the specified ca_name.
-P <ca_port> Uses the specified ca_port.
-t <timeout_ms> Overrides the default timeout for the solicited mads.
Table 36 - smpdump Flags and Options