The counter index is a QP attribute given in the QP context. Multiple QPs may be associated with
the same counter set, If multiple QPs share the same counter its value represents the cumulative
total.
• ConnectX®-3 support 127 different counters which allocated:
• 4 counters reserved for PF - 2 counters for each port
• 2 counters reserved for VF - 1 counter for each port
• All other counters if exist are allocated by demand
• RoCE counters are available only through sysfs located under:
• # /sys/class/infiniband/mlx4_*/ports/*/counters/
• # /sys/class/infiniband/mlx4_*/ports/*/counters_ext/
• Physical Function can also read Virtual Functions' port counters through sysfs located
under:
• # /sys/class/net/eth*/vf*_statistics/
To display the network device Ethernet statistics, you can run:
Ethtool -S <devname>
Table 7 - Port IN Counters
Counter Description
rx_packets Total packets successfully received.
rx_bytes Total bytes in successfully received packets.
rx_multicast_packets Total multicast packets successfully received.
rx_broadcast_packets Total broadcast packets successfully received.
rx_errors Number of receive packets that contained errors preventing them
from being deliverable to a higher-layer protocol.
rx_dropped Number of receive packets which were chosen to be discarded
even though no errors had been detected to prevent their being
deliverable to a higher-layer protocol.
rx_length_errors Number of received frames that were dropped due to an error in
frame length
rx_over_errors Number of received frames that were dropped due to overflow
rx_crc_errors Number of received frames with a bad CRC that are not runts,
jabbers, or alignment errors
rx_jabbers Number of received frames with a length greater than MTU octets
and a bad CRC
rx_in_range_length_error Number of received frames with a length/type field value in the
(decimal) range [1500:46] (42 is also counted for VLANtagged