Manual
Table Of Contents
- P7P55D-E Premium specifications summary
- About this guide
- Safety information
- Notices
- Chapter 1: Product introduction
- Chapter 2: Hardware information
- Chapter 3: BIOS setup
- 3.1 Knowing BIOS
- 3.2 Updating BIOS
- 3.3 BIOS setup program
- 3.4 Main menu
- 3.5 Ai Tweaker menu
- 3.5.1 Ai Overclock Tuner [Auto]
- 3.5.2 CPU Ratio Setting [Auto]
- 3.5.3 Intel(R) SpeedStep(TM) Tech [Enabled]
- 3.5.4 Intel(R) TurboMode Tech [Enabled]
- 3.5.5 Xtreme Phase Full Power Mode [Auto]
- 3.5.6 DRAM Frequency [Auto]
- 3.5.7 QPI Frequency [Auto]
- 3.5.8. DRAM Timing Control [Auto]
- 3.5.9 CPU Differential Amplitude [Auto]
- 3.5.10 CPU Clock Skew [Auto]
- 3.5.11 CPU Voltage Mode [Offset]
- 3.5.12 IMC Voltage [Auto]
- 3.5.13 DRAM Voltage [Auto]
- 3.5.14 CPU PLL Voltage [Auto]
- 3.5.15 PCH Voltage [Auto]
- 3.5.16 DRAM DATA REF Voltage on CHA/B [Auto]
- 3.5.17 DRAM CTRL REF Voltage on CHA/B [Auto]
- 3.5.18 Load-Line Calibration [Auto]
- 3.5.19 CPU Spread Spectrum [Auto]
- 3.5.20 PCIE Spread Spectrum [Auto]
- 3.6 Advanced menu
- 3.7 Power menu
- 3.8 Boot menu
- 3.9 Tools menu
- 3.10 Exit menu
- Chapter 4: Software support
- Chapter 5: Multiple GPU technology support

ASUS P7P55D-E Premium 4-15
Chapter 4
The navigation keys at the bottom of the screen allow you to move through the menus
and select the menu options.
The RAID BIOS setup screens shown in this section are for reference only and may not
exactly match the items on your screen.
The utility supports maximum four hard disk drives for RAID conguration.
Creating a RAID volume
To create a RAID set
1. From the utility main menu, select 1. Create RAID Volume and press <Enter>. The
following screen appears.
Intel(R) Matrix Storage Manager option ROM v8.9.0.1014 PCH-D wRAID5
Copyright(C) 2003-09 Intel Corporation. All Rights Reserved.
[ CREATE VOLUME MENU ]
[ HELP ]
Enter a unique volume name that has no special characters and is
16 characters or less.
[↑↓]Change [TAB]-Next [ESC]-Previous Menu [ENTER]-Select
Name: Volume0
RAID Level: RAID0(Stripe)
Disks: Select Disks
Strip Size: 128KB
Capacity: 0.0 GB
Sync: N/A
Create Volume
2. Enter a name for the RAID set and press <Enter>.
3. When the RAID Level item is selected, press the up/down arrow key to select a RAID
mode to create, and then press <Enter>.
4. When the Disks item is selected, press <Enter> to select the hard disk drives you want
to include in the RAID set. The SELECT DISKS screen appears.
[ SELECT DISKS ]
Port Drive Model Serial # Size Status
0 ST3160812AS 9LS0HJA4 149.0GB Non-RAID Disk
1 ST3160812AS 9LS0F4HL 149.0GB Non-RAID Disk
2 ST3160812AS 3LS0JYL8 149.0GB Non-RAID Disk
3 ST3160812AS 9LS0BJ5H 149.0GB Non-RAID Disk
Select 2 to 6 disks to use in creating the volume.
[
↑↓
]-Prev/Next [SPACE]-SelectDisk [ENTER]-Done