User’s Manual

Table Of Contents
5-28
第五章:RAID 磁盤陣列設置
E s c = E x i t M e n u F 1 / S h i f t + 1 = H e l p
SPACE/+/- = Change Item C = Commit Changes
LSI Logic Cong Utility v6.16.00.00 (2007.05.07)
Manage Hot Spare -- SAS1068E
Identier LSILOGICLogical Volume 3000
Type IME
Scan Order 0
Size(MB) 51498
Status Optimal
Slot Device Identier Hot Drive Pred Size
Num Spr Status Fail (MB)
0 SEAGATE ST373454SS 0003 [NO] Ok No 34331
1 SEAGATE ST373454SS 0003 [NO] Ok No 34331
2 SEAGATE ST373454SS 0003 [NO] Ok No 34331
3 SEAGATE ST373454SS 0003
[Yes] Hot Spare No 35003
[----] --------- -- -----
Esc = Exit Menu F1/Shift+1 = Help
Enter = Select Item
LSI Logic Cong Utility v6.16.00.00 (2007.05.07)
Manage Array -- SAS1068E
Identier LSILOGICLogical Volume 3000
Type IME
Scan Order 0
Size(MB) 51498
Status Optimal
Manage Hot Spare
Synnchronize Array
Activate Array
Delete Array
4. 使 h o t s pa r e
Hot Spr 列,按下 <+>/<-> 或空格鍵。Drive Status 列將顯示 Hot
Spare。按下 <C> 確認更改。
同步陣列
步陣允許具程序重同步列中像硬中的據。步驟
不需要使用,因為在一般的操作中,數據都會自動同步。
請依照以下步驟同步陣列:
1. 依照“查看卷屬性”部分的步驟 1–3 以及“管理 hot spare 硬盤”部
分的步驟 2 操作。
2. 在“Manage Array”畫面,選擇【Synchronize Array】,然後按下
<Enter>。
3. 按下 <Y> 開始同步,或按下 <N> 取消操作。