User Manual

5-10
第五章:RAID 磁盤陣列設置
[ESC]-Exit [ENTER]-Select Menu[ ]-Select
Intel(R) Rapid Storage Technology enterprise - SATA Option ROM - 3.6.0.1023
Copyright(C) 2003-12 Intel Corporation. All Rights Reserved.
[ MAIN MENU ]
[ DISK/VOLUME INFORMATION]
RAID Volumes: *=Data is Encrypted
ID Name Level1 Strip Size Status Bootable
1 Volume0 RAID1(Mirror) N/A 149.0GB Rebuild Yes
Physical Devices:
Port Drive Model Serial # Size Type/Status(Vol ID)
1 ST3160812AS 9LS0F4HL 149.0GB Member Disk(0)
2 ST3160812AS 3LS0JYL8 149.0GB Member Disk(0)
Volumes with “Rebuild” status will be rebuilt within the operating system.
3. Reset Disks to Non-RAID
4. Exit
1. Create RAID Volume
2. Delete RAID Volume
3. 選擇硬盤後程序自動開始重建。RAID volume 的狀態變為“Rebuild”。
4. 退出 Intel Rapid Storage Technology 並重啟系統。
5. 選擇開始 > 所有程序 > Intel Rapid Storage > Intel Rapid Storage Console 或點擊
Intel Rapid Storage Technology 圖標開啟 Intel Rapid Stroage Manager 程序。
6. View 菜單中,選擇Advanced Mode 顯示 Intel Rapid Storage Technology
信息。
7. Volumes view 項目中,選擇 RAID volume 查看重建狀態。完成後,狀態變為
“Normal”。
使用新硬盤重建 RAID 陣列
若任何包含 RAID 陣列的 SATA 硬盤失敗,系統在 POST 過程中顯示 RAID
volume 的狀態為“Degraded”。您可安裝新的硬盤重建 RAID 陣列。
請依照以下步驟使用新硬盤重建 RAID 陣列:
1. 卸除舊的 SATA 硬盤,在 SATA 連接端口上安裝一塊同樣規格的新 SATA
盤。
2. 重啟系統,接著根據 5-10 頁中的使用未設置 RAID 的硬盤重建 RAID 陣列部分
的步驟進行。
請選擇與原硬盤同樣容量的目的硬盤。