User Manual

Technical Reference
41
4.4 Reliability
The demonstrated Mean Time Between Failures (MTBF) is done through 24/7 testing. Full Intel®
NUC systems in chassis with memory, SSD or HDD, and a fan are ran at 100% on time for 90 days
continuously while running system wide stress inducing software in a 40 °C ambient air
temperature chamber. The demonstrated MTBF for Intel NUC Board NUC13AN is >50,000 hours.
4.5 Environmental
Table 19 lists the environmental specifications for the board.
CAUTION
If the external ambient temperature exceeds 40
o
C, further thermal testing is required to ensure
components do not exceed their maximum operating temperature.
Table 19. Environmental Specifications
Parameter
Specification
Temperature
Sustained Storage Limits (i.e.
warehouse)
-20 C to +40 C
Short Duration Limits (i.e. shipping)
-40 °C to +60 °C
Ambient Operating NUC Kit*
Up to 0 C to +40 C
Ambient Operating NUC Board*
0 C to +50 C (Local ambient temperature inside the chassis)
* Processor performance may automatically decrease when the system
operates in the top 5 °C of the ambient operating temperature ranges above.
Shock (Board)
Unpackaged
50 g trapezoidal waveform
Velocity change of 170 inches/s²
Packaged
Free fall package drop machine set to the height determined by the weight
of the package.
Product
Weight
(pounds)
Non-palletized Product
drop height (inches)
Palletized drop heights (single
product) (inches)
<20
36
N/A
21-40
30
N/A
41-80
24
N/A
81-100
18
12
100-120
12
9
Shock (System)
Unpackaged
25g trapezoidal waveform
Velocity = 250 inches/sec, 2 shock table drops in each of 6 directions