4.5 Environmental
Table 15 lists the environmental specifications for the system.
CAUTION
If the external ambient temperature exceeds 35
o
C, further thermal testing is required to ensure
components do not exceed their maximum operating temperature.
Table 15. Environmental Specifications
Parameter
Specification
Temperature
Sustained Storage Limits (i.e.
warehouse)
-20 °C to +40 °C
Short Duration Limits (i.e. shipping)
-40 °C to +60 °C
Ambient Operating – NUC Kit*
0 °C to +35 °C
* Processor performance may automatically decrease when the system
operates in the top 5 °C of the ambient operating temperature ranges above.
Shock (System)
Unpackaged 50 g trapezoidal waveform
Velocity change of 170 inches/s²
Packaged
Free fall package drop machine set to the height determined by the weight
of the package.
Product
Weight
(pounds)
Non-palletized Product
drop height (inches)
Palletized drop heights (single
product) (inches)
<20
36
N/A
21-40
30
N/A
41-80
24
N/A
81-100 18 12
100-120
12
9
Vibration (System)
Unpackaged/Packaged
Random profile 5 Hz @ 0.001 g^2/Hz to 20 Hz @ 0.01 g^2/Hz (slope up)
20 Hz to 500Hz @ 0.01 g^2/Hz (flat)
Input acceleration is 2.20gRMS
Note: The operating temperature of the system may be determined by measuring the air temperature from the junction
of the heatsink fins and fan, next to the attachment screw, in a closed chassis, while the system is in operation.
Note: Before attempting to operate this system, the overall temperature of the system must be above the minimum
operating temperature specified. It is recommended that the system temperature be at least room temperature
before attempting to power on the system. The operating and non-operating environment must avoid condensing
humidity.