User Manual

Technical Reference
31
5.4 Environmental
Table 14 lists the environmental specifications for the board.
CAUTION
If the external ambient temperature exceeds 35
o
C, further thermal testing is required to ensure
components do not exceed their maximum operating temperature.
Table 14. Environmental Specifications
Parameter
Specification
Temperature
Sustained Storage Limits (i.e.
warehouse)
-20 C to +40 C
Short Duration Limits (i.e. shipping)
-40 °C to +60 °C
Ambient Operating NUC Kit*
0 C to +35 C
Ambient Operating NUC Board*
0 C to +35 C
* Processor performance may automatically decrease when the system
operates in the top 5 °C of the ambient operating temperature ranges above.
Shock (Board)
Unpackaged
50 g trapezoidal waveform
Velocity change of 170 inches/s²
Packaged
Free fall package drop machine set to the height determined by the weight
of the package.
Product
Weight
(pounds)
Non-palletized Product
drop height (inches)
Palletized drop heights (single
product) (inches)
<20
36
N/A
21-40
30
N/A
41-80
24
N/A
81-100
18
12
100-120
12
9
Vibration (System)
Unpackaged
Random profile 5 Hz to 40 Hz @ 0.015 g^2/Hz to 500 Hz @ 0.00015
g^2/Hz(slope down)
Input acceleration is 1.09 gRMS
Packaged
Random profile 5 Hz to 40 Hz @ 0.015 g^2/Hz to 500 Hz @ 0.00015
g^2/Hz(slope down)
Input acceleration is 1.09 gRMS
Note: The operating temperature of the board may be determined by measuring the air temperature from the junction of
the heatsink fins and fan, next to the attachment screw, in a closed chassis, while the system is in operation.
Note: Before attempting to operate this board, the overall temperature of the board must be above the minimum
operating temperature specified. It is recommended that the board temperature be at least room temperature
before attempting to power on the board. The operating and non-operating environment must avoid condensing
humidity.