2.11 Environmental
Table 11 lists the environmental specifications for the Intel® NUC 11 Compute Element.
Table 11. Environmental Specifications
Parameter
Specification
Temperature
Non-Operating
-40 C to +60 C
Operating
Minimum of 0 C. Maximum local ambient operating temperature limitations are a
function of the carrier board and carrier board enclosure design and as such a specific
number cannot be provided.
Shock
Unpackaged
25 g trapezoidal waveform
Velocity change of 250 inches/s²
Packaged
Free fall package drop machine set to the height determined by the weight of the package.
Product Weight (pounds)
Free Fall (inches)
<20
36
21-40
30
41-80
24
81-100
18
Vibration
Unpackaged
5 Hz to 20 Hz: 0.01 g²/Hz sloping up to 20 Hz @ 0.02 /Hz
20 Hz to 500 Hz: 0.02 /Hz (flat)
Input acceleration is 3.13 g RMS
Packaged
40 Hz to 500 Hz: 0.015 g²/Hz sloping down to 0.00015 g²/Hz
Input acceleration is 1.09 g RMS
Note: Before attempting to operate the Intel® NUC 11 Compute Element, the overall temperature of the system must be
above the minimum operating temperature specified. It is recommended that the system temperature be at least
room temperature before attempting to power on the NUC 11 Compute Element. The operating and non-
operating environment must avoid condensing humidity.